background image

Hearthstone Quality Home Heating Products, Inc.

                                                   

 

STOWE Model 8324

 

25 

 

avant  d’être  utilisé  et  au  moins  une  fois  l’an  par  la 
suite.  Des  nettoyages  plus  fréquents  peuvent  être 
nécessaires  si  les  tapis,  la  literie,  et    cetera 
produisent  une  quantité  importante  de  poussière.  Il 
est  essentiel  que  les  compartiments  abritant  les 
commandes,  les  brûleurs  et  les  conduits  de 
circulation d’air de l’appareil soient tenus propres.

 

 

AS NEEDED 

 

Glass and Gasket Replacement 

In  the  event  that  you  need  to  repair  or  replace  a 
cracked  or  broken  glass,  order  kit  93-58230  
(complete  glass  assembly  with  frame)  and  use  the 
following  instructions  to  replace  the  components. 
Your  Stowe  uses  a  folded  flat  fiberglass  gasket  to 
make  a  tight  seal  between  the  glass  frame  and  the 
firebox.  In  time,  the  gasket  can  become  brittle  and 
compressed  and  should  be  replaced  using  the 
following  instructions.  New  gasket  material  is  also 
available  from  your  Authorized  Hearthstone  Dealer. 
Protect  your  hands  with  work  gloves,  and  wash  up 
later. 

1.  Allow the Stowe to cool completely. If the glass 

is severely broken, first pull the broken 
fragments of glass away from the firebox using 
heavy-duty gloves.   

2.  Follow the instructions for removing the front 

glass described in Firebox Access on page 8.  
Remove the glass from the glass frame by 
drilling 

out the four 1/8” rivets that lock the glass 

in place. Pull the glass away from the frame and 
set it aside. 
 

If replacing gasket only: 
 
1.  Remove  the  existing  gasket  from  the  glass  by 

grasping one end and pulling firmly. Clean off as 
much of the hanging fiber 

“hairs” as possible 

2. 

Locate the 3/4” x 1/16” flat tape gasket. Peel the 
adhesive  protecting  paper  away  from  one  end.  
Starting at the center of the long end of the glass 
apply  the  gasket  centered  on  the  edge  of  the 
glass.    Continue  to  wrap  the  gasket  around  the 
edge until you meet at the starting point. Do not 
overlap  the  gasket  ends  or  leave  ends  with 
ragged edges. 

3.  Firmly  and  evenly,  fold  the  gasket  around  the 

edges of the glass so it lies flat on the surface. 

4.  Place  the  gasket  back  in  the  glass  frame.  With 

four  new  1/8”  rivets  replace  the  2  glass  clips. 
The glass and frame are now ready to be placed 
back on the unit. 
 

If replacing entire glass with kit: 

1.  Apply gasket to new glass as describe in steps 

2-3 above. 

2.  Carefully install the new glass with frame onto 

the firebox and fasten in place using the swing 
clips . 

3.  Replace the cast iron by reversing the steps 

used for removal.  

 

 

WARNING! DO NOT USE SUBSTITUTE 
MATERIALS. USE ONLY PARTS SUPPLIED BY 
HEARTHSTONE THROUGH AN AUTHORIZED 
HEARTHSTONE DEALER. 

 

 

CAUTION! DO NOT CLEAN THE GLASS WHILE 
THE UNIT IS HOT. 

 

 

VENTING

 

COMPONENTS: 

 

Venting should not need to be disassembled for 
normal cleaning.  However, if venting is required to 
be removed for any reason, this should be done by a 
qualified service person only.  It is imperative that 
the venting system be reinstalled according to the 
particular manufacturer’s specifications and this is 
best performed by a professional. 

 

Venting System Inspection 

Periodic inspection of the venting system should be 
performed by a qualified service person or agency at 
least annually.   
 
 

Summary of Contents for Stowe 8324

Page 1: ...t perform installation and service of this appliance In the Commonwealth of Massachusetts all installation of gas lines and gas fittings must be performed by a licensed gas fitter or licensed plumber...

Page 2: ...Page 1 of 33 Intentionally Blank...

Page 3: ...pt in a safe place as proof of purchase Serial Number Fuel type Natural Gas Liquid Propane Sold by Date of Purchase Address Phone E mail Website Installed by Date of Installation Address Phone E mail...

Page 4: ...loor Protection 9 Venting Information 10 Venting Connection 10 Approved Systems 11 Minimum Venting 12 Electrical System Information 16 Gas Supply Connections 17 Gas Connections 18 Initial Leak Check 1...

Page 5: ...s 02202 Manufactured and Warranted by Hearthstone Quality Home Heating Products Inc 317 Stafford Ave Morrisville VT 05661 8695 USA www hearthstonestoves com Figure 1 Stowe DV Dimensions Specification...

Page 6: ...nit will remain appealing while providing years of quality performance The installation must conform to local codes or in the absences of local codes the current National Fuel Gas Code ANSI Z223 1 NFP...

Page 7: ...E COMPARTIMENT DES COMMANDES SONT PROPRES VOIR LES INSTRUCTIONS D INSTALLATION ET D UTILISATION QUI ACCOMPAGNENT L APPAREIL Hot Surfaces Certain exposed surfaces of the Stowe will reach high temperatu...

Page 8: ...INSTALLATION PREPARATION CODES Adhere to all local codes or in their absence the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223 1 NFPA 54 or CAN CGA B149 Installer l appareil selon les codes o...

Page 9: ...still occur during transit Take care to inspect for damage when unpacking and installing the unit DO NOT INSTALL OR PUT INTO SERVICE A DAMAGED OR INCOMPLETE HEATER Remove the shrink wrap and other pa...

Page 10: ...adequate ventilation Minimum clearances to combustibles must be maintained as shown in Figures 5 8 Note The rear clearance to combustibles is determined by either the unit s or the vent pipe s minimum...

Page 11: ...tone Quality Home Heating Products Inc STOWE Model 8324 10 Figure 5 Minimum Wall Clearances Figure 6 Corner Clearances Figure 7 Horizontal Vent Mantle Clearance Figure 8 Snorkel Termination Mantle Cle...

Page 12: ...RNING IN HIGH WIND AREAS AND PARTICULARLY COLD CLIMATES IT MAY BE NECESSARY TO HEAT YOUR VENT SYSTEM WITH THE PILOT PRIOR TO IGNITION OF THE MAIN BURNER IN THESE INSTANCES IT IS RECOMMENDED THAT YOU L...

Page 13: ...88 1999 CSA 2 33 M99 test methods this installation has been tested and approved by Intertek Testing Services with an appropriate test The code authority having jurisdiction must be consulted prior to...

Page 14: ...e wall Ensure both of the retaining straps extend through interior wall thimble Before attaching the vent termination to the outside of the house run a bead of non hardening mastic around its outside...

Page 15: ...CAN We strongly recommend 12 inches particularly where strong winds prevail H Not to be installed within 15 feet 4 5m above a meter regulator assembly within 3 feet 91cm horizontally from the center l...

Page 16: ...Hearthstone Quality Home Heating Products Inc STOWE Model 8324 15 Figure 13 Venting Termination Diagram...

Page 17: ...ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING ATTENTION AU MOMENT DE L ENTRETIEN DES COMMANDES TIQUETEZ TOUS LES FILS AVANT LE D BRANCHEMENT DES ERREURS DE...

Page 18: ...es equal to or greater than psig Over pressurizing can damage the control resulting in leakage or control malfunction NOTICE A QUALIFIED TECHNICIAN MUST CONNECT THE HEATER TO THE GAS SUPPLY AND LEAK T...

Page 19: ...a fire or explosion GAS CONNECTIONS Connection Main Gas Tubing connections 1 Do NOT use pipe joint compound or Teflon PTFE tape 2 Slip nut and ferrule over tubing 3 Slide nut and ferrule into place a...

Page 20: ...gs will last a long time however they will break if subjected to rough or improper handling Exact positioning of the log set is required in order to obtain a pleasing flame pattern and efficient combu...

Page 21: ...n 7 Place small tufts of the Platinum Bright Embers on the burner and log surfaces for additional glow as desired do not block burner ports Figure 24 Platinum Bright Embers Enlarged to Show Detail REM...

Page 22: ...l valve Before lighting smell or use a gas detector all around the appliance area to check for gas leaks Be sure to test near the floor because some gases LPG are heavier than air and will settle on t...

Page 23: ...erly adjusted and installed thermostat By adjusting the variable output control located on the gas control valve the rate of heat output is varied to meet the heating requirements of the season Choosi...

Page 24: ...aft if necessary Controlling the draft also changes the aesthetics of the flame The restrictor plate has a large range of unlimited settings see Figures 29 30 The adjustment point is on the left side...

Page 25: ...dic cleaning to prevent the accumulation of dust lint and other debris To clean the firebox set the switch to the OFF position and turn off the gas supply to the valve When the unit is cool remove the...

Page 26: ...rom the glass by grasping one end and pulling firmly Clean off as much of the hanging fiber hairs as possible 2 Locate the 3 4 x 1 16 flat tape gasket Peel the adhesive protecting paper away from one...

Page 27: ...0 VALVE SIT UNIVERSAL 3160 107 GASKET REAR ORIFICE PLATE 7211 370 PILOT TOP CONV 3 WAY 3160 150 GASKET HEAT EXCHANGER 4 x14 5 7211 588 BURNER 3160 152 GASKET PILOT 1 75 x3 ADHESIVE BACK 3160 155 GASKE...

Page 28: ...er sitting for off season summer pilot assembly may be dirty E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas press...

Page 29: ...bly If the meter reading is OK but the burner does not come on replace the gas valve C Plugged burner orifice C Remove and check burner orifice clean or replace Note do not use any metal cleaning devi...

Page 30: ...lear obstructions B3 Clear obstructions C If gas pressures are correct and the flames stay the same adjust the air shutter for a proper burn 9 Burner flashback Air gas mixture ignites inside the burne...

Page 31: ...Hearthstone Quality Home Heating Products Inc STOWE Model 8324 30 07044 2 RATING LABEL...

Page 32: ...ot listed elsewhere Any parts repaired or replaced during the limited warranty period will be warranted under the terms of the limited warranty for a period not to exceed the remaining term of the ori...

Page 33: ...Such parts that are subject to normal wear and tear during the warranty period such as paint gaskets baffles refractory materials ash grates and glass 4 Damage resulting from installation modificatio...

Page 34: ...rts for repair the return of the appliance for repair or to schedule a Dealer service call The Original Purchaser should refer to the Dealer Network search engine contained on Hearthstone s Web site w...

Reviews: