background image

Hearthstone Quality Home Heating Products, Inc. 

   Stowe DX Model 8322 

 

 

 

COMPARTIMENT DES COMMANDES SONT 
PROPRES.  VOIR LES INSTRUCTIONS 
D’INSTALLATION ET D’UTILISATION QUI 
ACCOMPAGNENT L’APPAREIL.) 

Hot Surfaces 

Certain  exposed  surfaces  of  the  Stowe  will  reach 
high 

temperatures 

during 

normal 

operation.  

Clearances to combustibles must be maintained,  as 
specified  in  the  “Clearances  To  Combustibles” 
section of this manual.  
 

 

DUE  TO  HIGH  TEMPERATURES  THE  APPLIANCE 
SHOULD  BE  LOCATED  OUT  OF  TRAFFIC  AND 
AWAY 

FROM 

FURNITURE, 

DRAPERIES, 

CLOTHING  AND  FLAMMABLE  MATERIALS.

    EN 

RAISON 

DES 

TEMPÉRATURES 

ÉLEVÉES, 

L’APPAREIL DEVRAIT ÊTRE INSTALLÉ DANS UN 
ENDROIT  OÙ  IL  Y  A  PEU  DE  CIRCULATION  ET 
LOIN DU MOBILIER ET DES TENTURES 

 

CHILDREN  AND  ADULTS  SHOULD  BE  ALERTED 
TO 

THE 

HAZARDS 

OF 

HIGH 

SURFACE 

TEMPERATURES  AND  SHOULD  STAY  AWAY  TO 
AVOID BURNS TO SKIN OR CLOTHING IGNITION. 

LES  ENFANTS  ET  LES  ADULTES  DEVRAIENT 
ÊTRE  INFORMÉS  DES  DANGERS  QUE  POSENT 
LES TEMPÉRATURES DE SURFACE ÉLEVÉES ET 
SE  TENIR  À  DISTANCE  AFIN  D’ÉVITER  DES 
BRÛLURES  OU  QUE  LEURS  VÊTEMENTS  NE 
S’ENFLAMMENT.

 

 

CAREFULLY  SUPERVISE  YOUNG  CHILDREN 
WHEN  THEY  ARE  IN  THE  SAME  ROOM  AS  THE 
APPLIANCE.  TODDLERS,  YOUNG  CHILDREN, 
AND  OTHERS  MAY  BE  SUSCEPTIBLE  TO 
ACCIDENTAL  CONTACT  BURNS.  A  PHYSICAL 
BARRIER  IS  RECOMMENDED  IF  THERE  ARE  AT 
RISK INDIVIDUALS IN THE HOUSE. TO RESTRICT 
ACCESS  TO  A  FIREPLACE  OR  STOVE,  INSTALL 
AN  ADJUSTABLE  SAFETY  GATE  TO  KEEP 
TODDLERS,  YOUNG  CHILDREN,  AND  OTHER  AT 
RISK  INDIVIDUALS  OUT  OF  THE  ROOM  AND 
AWAY  FROM  HOT  SURFACES. 

LES  JEUNES 

ENFANTS 

DEVRAIENT 

ÊTRE 

SURVEILLÉS 

ÉTROITEMENT  LORSQU’ILS  SE  TROUVENT 
DANS  LA  MÊME  PIÈCE  QUE  L’APPAREIL.  LES 
TOUT  PETITS,  LES    JEUNES  ENFANTS  OU  LES 
ADULTES  PEUVENT  SUBIR  DES  BRÛLURES 
S’ILS  VIENNENT  EN  CONTACT  AVEC  LA 
SURFACE  CHAUDE.  IL  EST  RECOMMANDÉ 
D’INSTALLER UNE BARRIÈRE PHYSIQUE SI DES 
PERSONNES  À RISQUES HABITENT LA  MAISON. 
POUR  EMPÊCHER  L’ACCÈS  À  UN  FOYER  OU  À 
UN  POÊLE,  INSTALLEZ  UNE  BARRIÈRE  DE 
SÉCURITÉ;  CETTE  MESURE  EMPÊCHERA  LES 
TOUT PETITS, LES JEUNES ENFANTS ET TOUTE 

AUTRE PERSONNE À RISQUE D’AVOIR ACCÈS À 
LA PIÈCE ET AUX SURFACES CHAUDES.

 

 

CLOTHING  OR  OTHER  FLAMMABLE  MATERIAL 
SHOULD  NOT  BE  PLACED  ON  OR  NEAR  THE 
APPLIANCE.

 

ON  NE  DEVRAIT  PAS  PLACER  DE 

VÊTEMENTS 

NI 

D’AUTRES 

MATIÈRES 

INFL

AMMABLES 

SUR 

L’APPAREIL 

NI 

À 

PROXIMITÉ. 

 

CLEAN THE AREA AROUND, UNDER, AND BEHIND THE 
UNIT ON A REGULAR BASIS TO PREVENT THE 
ACCUMULATION OF DUST AND LINT.

 

Ceramic Logs, Burner, & Baffle

 

If  the  decorative  ceramic  log,  burner,  or  baffle 
material  supplied  with  the  Stowe  is  damaged  or 
parts  are  missing,  they  must  be  replaced  with  the 
same,  or  approved  Hearthstone  replacement  parts. 
These  components  affect  the  combustion  quality 
and  safety  of  the  heater.  Do  not  replace  ceramic 
logs,  the  burner,  or  baffle  with  unapproved  ceramic 
components or any other material.  

 

We recommend  you always wear  gloves and safety 
goggles  while  handling  the  ceramic  log  set,  Heat 
Wave baffle, and burner materials. 

Electrical Hazard 

If  present,  any  three-prong  grounded  plug  must  be 
plugged  directly  into  a  properly  grounded  three-
prong  receptacle.  Do  not  cut  or  remove  the 
grounding prong from any plug or otherwise attempt 
to circumvent the grounding protection provided with 
the unit. The Stowe must be electrically grounded in 
accordance  with  local  codes,  or  in  the  absence  of 
local  codes,  with  the  National  Electrical  Code, 
ANSI.NFPA  70  in  the  U.S.  or  CSA  C22.1  Canadian 
Electrical Code in Canada.  

Do Not Light Pilot or Burner by Hand 

The  pilot  light  on  this  gas  heater  is  lit  by  using  an 
electronic ignition module as described elsewhere in 
this  manual.  Never  attempt to light  the  pilot  or  main 
burner by hand with a match or lighter. 

Mobile Home Installations 

This  appliance  may  be  installed  as  an  aftermarket 
appliance  in  a  permanently  located,  manufactured 
(mobile) home, where not prohibited by local codes. 

(Cet  appareil  peut  être  installé  dans  un  maison 
préfabriquée (mobile) déjá installée á demeure si les 
réglements locaux le permettent. 

f i r e - p a r t s . c o m

Summary of Contents for Stowe DX 8322

Page 1: ...A qualified installer service agency or gas supplier must perform installation and service of this appliance In the Commonwealth of Massachusetts all installation of gas lines and gas fittings must b...

Page 2: ...Intentionally Blank fire parts com...

Page 3: ...our original receipt in a safe place as proof of purchase Serial Number Fuel type Natural Gas Liquid Propane Sold by Date of Purchase Address Phone E mail Website Installed by Date of Installation Add...

Page 4: ...rotection 17 VENTING INFORMATION 19 Venting Components 19 Minimum Venting Installation Instructions 22 ELECTRICAL SYSTEM INFORMATION 25 GAS SUPPLY CONNECTIONS 27 Gas Connections 28 HEAT WAVE BAFFLE LO...

Page 5: ...ter draft in colder climates 7 Battery backup for functionality during power outages Control System Features 1 Proflame GTMF System a Thermostatic Remote Control i Six 6 flame levels adjustable via th...

Page 6: ...and flammable material Vent Only to the Outside Never vent the gas heater to other rooms or buildings Service Caution If you believe your Stowe is not in any way performing properly immediately disco...

Page 7: ...U UN PO LE INSTALLEZ UNE BARRI RE DE S CURIT CETTE MESURE EMP CHERA LES TOUT PETITS LES JEUNES ENFANTS ET TOUTE AUTRE PERSONNE RISQUE D AVOIR ACC S LA PI CE ET AUX SURFACES CHAUDES CLOTHING OR OTHER F...

Page 8: ...Hearthstone Quality Home Heating Products Inc Stowe DX Model 8322 8 fire parts com...

Page 9: ...20V 60Hz power outlets The Fan outlet controls the fan speed through six levels and the Auxiliary outlet either on or off There is also an additional constantly powered 120V 60Hz outlet The system has...

Page 10: ...perly grounded three prong receptacle Do not cut or remove the grounding prong from the plug Proflame DFC Ignition Module This is the command center for the appliance The DFC Module allows the pilot t...

Page 11: ...to CPI regardless of the position of the receiver switch Intermittent Pilot IPI Using the IPI mode is a more efficient use of fuel as the pilot only ignites when the thermostat calls for heat Figure 2...

Page 12: ...both Thermostat Key This is the function that sets either the Manual or Smart thermostatic control UP Down Arrow Key Adjusts the thermostat temperature range flame settings and fan speed Mode Key Tog...

Page 13: ...umbers Gasfitters 100 Cambridge Street Room 1511 Boston MA 02202 www mass gov Figure 6 Model 8322 Dimensions Specification NG LP INPUT RATING Btu hr 0 2000 ft 25 000 25 000 INPUT RATING Btu hr 2000 45...

Page 14: ...s une maison pr fabriqu e U seulement ou mobile et doit tre install selon les instructions du fabricant et conform ment la norme Manufactured Home Construction and Safety Standard Title 24 CFR Part 32...

Page 15: ...fire logs burner and Heat Wave baffle Use care when handling these parts as they are fragile and subject to damage and breakage if handled roughly See the firebox access instructions on page 16 Unpac...

Page 16: ...ace Figure 7 Grille Removal Figure 8 Top Removal 2 Release the front panel by disengaging the two spring clips at its top tilt the front toward you slightly and lift it up out of the bottom slots and...

Page 17: ...or a rear exit through the wall vent pipe Ensure you consider the need for access to the gas control valve access door on the front of the unit as well as full access for periodic cleaning and servici...

Page 18: ...Products Inc Stowe DX Model 8322 18 Figure 13 Snorkel Termination Mantle Clearance The corner clearance for the Stowe 8322 is 4 measured from the edge of the top castings to the adjacent wall Figure 1...

Page 19: ...NING IN HIGH WIND AREAS AND PARTICULARLY COLD CLIMATES IT MAY BE NECESSARY TO HEAT YOUR VENT SYSTEM WITH THE PILOT PRIOR TO IGNITION OF THE MAIN BURNER IN THESE INSTANCES IT IS RECOMMENDED THAT YOU LE...

Page 20: ...9 CSA 2 33 M99 test methods this installation has been tested and approved by Intertek Testing Services with an appropriate test The code authority having jurisdiction must be consulted prior to proce...

Page 21: ...strongly recommend 12 inches particularly where strong winds prevail H Not to be installed within 15 feet 4 5m above a meter regulator assembly within 3 feet 91cm horizontally from the center line of...

Page 22: ...nsure both of the retaining straps extend through interior wall thimble Before attaching the vent termination to the outside of the house run a bead of non hardening mastic around its outside edges so...

Page 23: ...sition until you install the Heat Wave baffle then set to the fully opened position This ensures proper flames for a wide variety of vent configurations and efficiency The restrictor plate consists of...

Page 24: ...Hearthstone Quality Home Heating Products Inc Stowe DX Model 8322 24 Figure 21 Venting Termination Diagram fire parts com...

Page 25: ...TIEN DES COMMANDES TIQUETEZ TOUS LES FILS AVANT LE D BRANCHEMENT DES ERREURS DE C BLAGE PEUVENT ENTRA UN FONCTIONNEMENT INADEQUATE ET DANGEREUX This appliance is equipped with a three prong grounding...

Page 26: ...Hearthstone Quality Home Heating Products Inc Stowe DX Model 8322 26 Figure 23 Proflame GTMF Component Specifications fire parts com...

Page 27: ...E UNIT MUST BE INSTALLED AND CONNECTED IN ACCORDANCE WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WITH THE MOST CURRENT EDITION OF THE NATIONAL FUEL GAS CODE ANSI Z223 1 NFPA 54 OR CAN CGA B149 I...

Page 28: ...cted to the gas supply the supply line and manifold gas pressures must be tested The supply line pressure is tested to ensure it meets the minimum gas supply pressure as listed in the specifications f...

Page 29: ...t The ceramic logs will last a long time however they will break if subjected to rough or improper handling Exact positioning of the log set is required in order to obtain a pleasing flame pattern and...

Page 30: ...too tight 6 You are now ready to adjust the restrictor plate and install the log set Installation of the Log Set Refer to the following images in this section for log set assembly 1 Remove the packag...

Page 31: ...urfaces for additional glow as desired do not block burner ports Figure 37 Platinum Bright Embers Enlarged to Show Detail Removal of Log Set CAUTION THE LOG SET BURNER AND EMBERS RETAIN HEAT AND CAN B...

Page 32: ...and assembly of the unit Open windows to vent the room if necessary The off gassing and fumes will subside after the first 10 to 20 minutes of operation Odors and Impurities A heater of this type may...

Page 33: ...in incomplete combustion low efficiency and a dirty burn There are two simple guidelines to aid in determining the correct flame pattern 1 If the flame just above the surface of the burner or at the b...

Page 34: ...is easily operated once installed and adjusted by qualified service personnel The unit is controlled via the ON REMOTE OFF switch on the Receiver or by the Remote Control With the Receiver switch set...

Page 35: ...tact qualified service personnel To Turn off Gas and Shut Down the Appliance 1 Close the shut off in the gas supply to the valve 2 Set the thermostat to the OFF position or turn the ON OFF T STAT or O...

Page 36: ...AL EN VERRE N EST PAS EN PLACE EST CRAQU OU BRIS CONFIEZ LE REMPLACEMENT DU PANNEAU UN TECHNICIEN AGR NOTE If the venting system is disassembled for any reason re install per the instructions provided...

Page 37: ...m carpeting bedding material etc It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean L installation et la r paration devrait tre confi es...

Page 38: ...27 X3 8 COMP 3160 107 GASKET REAR ORIFICE PLATE 7211 101 DFC PROFLAME CONTROL BOARD 3160 150 GASKET HEAT EXCHANGER 4 x14 5 7211 102 WIRE HARNESS DFC 3160 152 GASKET PILOT 1 75 x3 ADHESIVE BACK 7211 1...

Page 39: ...ssure B Faulty connections C Pilot dirty or plugged A Check for proper inlet pressure for the fuel gas in use B Check connections on the valve C Clean or replace the pilot assembly 3 Pilot burning no...

Page 40: ...system may be too restrictive or blocked the rate at which the exhaust leaves draft determines the rate at which the combustion air is delivered Poor draft results in insufficient air delivery or a re...

Page 41: ...Hearthstone Quality Home Heating Products Inc Stowe DX Model 8322 41 Rating Label fire parts com...