E
LECTRICAL
C
ONNECTIONS
NOTE: open valve door on the lower front of unit for electrical and gas connections.
T
HERMOSTAT
The ON/OFF/T’stat switch or wall mounted
thermostat controls the Tribute DV. We
recommend installation of the thermostat for more
comfortable performance, however you may still
override the thermostat by setting the switch to
“ON”. The thermostat controls the unit by “calling for
heat.” The thermostat turns the unit on when the
room is cold, and turns the unit off once the room is
warmed sufficiently. The thermostat is controlled by
a 750 millivolt DC two-wire circuit.
R
EMOTE
C
ONTROL
There are two different optional remote controls
available for the Tribute DV. Both of the remote
controls are capable of turning the unit on and off.
One of the optional remotes also allows you to
control the temperature of the stove, (in the same
way the thermostat controls the heater), from
anywhere in the vicinity of the unit. If “ON” & “OFF”
are the only controls required, Kit #90-56912 can be
used. If you would like to control the temperature
via the remote control, use Kit #90-56914.
Installation instructions are provided with the kits.
T
HERMOSTAT
P
LACEMENT
The thermostat should be placed in the same room
or living space as the unit. Typically 5’ (1.5m) off the
floor and away from any influences that may cause
the temperature in the vicinity of the thermostat to
be unrepresentative of the room temperature in
general. Such influences might include strong
lighting, a heater vent from the central heating
system, or a nearby drafty window.
Placement of the thermostat on an inside wall
rather than an outside wall is preferable. Do not
place the thermostat directly behind or too close to
the unit, otherwise heat from the unit will
immediately satisfy the thermostat and turn the unit
off.
T
HERMOSTAT
W
IRING
The thermostat should be connected to the Tribute
DV using no more than 40’ (12 m) of the provided
insulated thermostat wire. The thermostat wire from
the Tribute DV to the thermostat can be surface
mounted or routed under the floor, through walls,
etc.
Be sure to leave a small coil of additional
thermostat wire behind the Tribute DV so that the
unit can be moved out of position for servicing and
cleaning.
Connect one of the thermostat wires to the gas
control marked
TH
and the other to the yellow wire
coming from the on/off T’stat switch
.
When making
these connections, position the thermostat wire so
that it extends towards the wall behind the Tribute
DV, then towards the thermostat.
At the thermostat, the wires should be connected to
the two connection screws on the back of the
thermostat per the instructions received with the
thermostat. Take care not to over-tighten the
connection screws and not to damage the internal
parts of the thermostat.