Hearthstone Quality Home Heating Products, Inc.
Tribute DV Model #8050
26
IGNITER
THERMOCOUPLE
PILOT
FLAME
THERMOPILE
PILOT CLIP
Figure 10: Pilot assembly
WARNING:
THE CONTROL HAS AN INTERLOCK
DEVICE. IF THE STOVE HAS BEEN LIT, IT WILL
NOT RELIGHT IMMEDIATELY. AFTER SHUTTING
OFF ALL GAS FLOW, THE PILOT BURNER
CANNOT BE RELIT UNTIL THE THERMOCOUPLE
HAS COOLED, ALLOWING THE
ELECTROMAGNET TO BE RELEASED (APPROX.
60 SEC.). THE GAS CONTROL KNOB IS
DESIGNED TO OPERATE BY HAND. DO NOT
USE ANY TOOLS DURING THIS OPERATION.
B
URNER
F
LAME
A
PPEARANCE
Once the unit is lit, observe the flame pattern and
adjust as necessary. Also, a periodic visual check
of the burner flame should be performed. The
burner flames can be adjusted by means of the air
shutter. To determine if the burner flame needs
adjustment, it is necessary to view the flame pattern
with the variable output control knob at its highest
setting (turn fully clockwise). Allow the unit to
operate for 10 minutes enabling the entire unit to
reach temperature and for the flame pattern to
stabilize. The flame pattern should be similar to the
one shown in Figure 11. There are several
guidelines to aid in determining if the flame pattern
is correct:
1. The flame should not be dirty, smoky, sooty, or
lick the top of the stove.
2. The flame should not rise off the TEK burner;
this is called “lifting”.
3. Flames should not impinge heavily on the log
set. They should “fit” through the pre-formed
spaces designed in the log set.
Figure 11: Typical flame appearance