Hearthstone Quality Home Heating Products, Inc.
Tribute DV Model #8050
8
O
WNER
’
S
I
NFORMATION
The installation must conform with local codes or,
in the absences of local codes, the current National
Fuel Gas Code, ANSI Z223.1 (NFPA 54) or
CAN/CSA B149 Installation Code.
(Installer
l’appareil selon les codes ou règlements locaux,
ou, en l’absence de tels règlements, selon les
Codes d’installation CAN/CSA-B149.)
D
AILY
O
PERATION
The Tribute DV is easily operated by the homeowner
once installed and adjusted by qualified service
personnel. The unit can be controlled via the wall-
mounted thermostat during the heating season. Set
the thermostat to the desired room temperature and
the unit will cycle on and off as required. By
adjusting the variable output control located on the
gas control valve, the rate of heat output can be
varied to meet the heating requirements of the
season. Choosing a low flame setting will result in
longer burn cycles at a reduced output, while
choosing a high flame setting will result in a shorter,
hotter burn cycle. Through trial and error, the
homeowner can select the optimum flame size for
their setting and application.
E
FFICIENCY
During the summer non-heating season, switch the
wall thermostat to “OFF”, and turn off the pilot. This
will improve the overall efficiency of the unit as the
heat from the pilot is wasted. When putting the unit
back into service, follow the lighting instructions
described on page 24.
C
ONDENSATION
Fuel gasses produce water vapor when burned.
Therefore, when the unit is first lit, especially when
cool, it is normal to experience some condensation
on the inside of the window glass. This condensation
will burn off within the first few minutes of operation.
If continuous condensation on the window glass or
dripping water from any part of the unit or venting
system (chimney) is noted, immediately discontinue
operation of the unit and contact qualified service
personnel.
C
LEANING
Clean the area around, under, and behind the unit
on a regular basis to prevent the accumulation of
dust and lint.
The Tribute DV requires minimal routine
maintenance and care. It should always be cool and
off when being cleaned, or serviced. Once a year,
the unit, and venting system should be inspected by
qualified service personnel to insure that they are
clean, free of obstruction, safe, and in good working
order. If service or maintenance is required,
qualified service personnel should perform it.
S
ERVICE
C
AUTION
If you believe your Tribute DV is not, in any way,
performing properly, immediately discontinue
operation until the unit has been inspected and
approved by qualified service personnel. Prior to
servicing the unit, turn the valve control knob
clockwise to “OFF”. The unit should be cool prior to
servicing and cleaning. Use of any components not
supplied by Hearthstone on the stove voids all
warranties.
Do not substitute components.