Hearthstone Quality Home Heating Products, Inc.
Tribute DV Model #8050
9
I
NSTALLER
’
S
I
NFORMATION
C
ODES
Adhere to
all
local codes
or, in their absence, the
latest edition of THE NATIONAL FUEL GAS CODE
ANSI Z223.1 (NFPA 54) or CAN/CSA B149
Installation Code that can be obtained from:
AMERICAN NATIONAL STANDARDS INSTITUTE, INC.
1430 BROADWAY
NEW YORK, NY 10018
www.ansi.org
OR
NATIONAL FIRE PROTECTION ASSOCIATION, INC.
BATTERY MARCH PARK
QUINCY, MA 02269
www.nfpa.org
The appliance, when installed with a blower, must
be electrically connected and grounded in
accordance with local codes or, in the absence of
local codes, with the current NFPA 70-National
Electrical Code or CSA C22.1-Canadian Electric
Code.
A manufactured home (mobile) OEM installation
must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR,
Part 3280 (U.S.) or Standard for Manufactured
Home Installation, ANSI/NCBCS A225.1 or Standard
for Gas Equipped Recreational Vehicles and mobile
Housing, CSA Z240.4.CAN/SCA Z240 MH
(Canada).
(Installer l’appareil selon les codes ou
règlements locaux, ou, en l’absence de tels
règlements, selon les Codes d’installation
CAN/CSA-B149.)
I
TEMS
R
EQUIRED FOR
I
NSTALLATION
External regulator (for propane/L.P.G. only)
Piping which complies with local codes
Pipe sealant approved for use with
propane/L.P.G. (resistant to sulfur compounds)
Manual
shutoff
valve
Sediment trap (see page 17)
Tee
joint
Pipe
wrench
Phillips
head
screwdriver
7/16-inch
wrench
Other parts as required by local code
*Safety
Glasses
*Gloves
P
ACKING
L
IST
1-Tribute DV Gas-Fired Heater
1-TEK Burner
5-Decorative TEK Fire logs
1- Bag Platinum Bright Embers
1-Owner’s Manual
1-Thermostat
1-40’ Thermostat wire
1-Warranty Validation Form
Note: Vent kits and components are supplied
separately. Failure to use the venting components
specified by Hearthstone QHHP, Inc. will void your
warranty and could risk a fire.
U
NPACKING AND
I
NSPECTION
Unpack and Inspect for Damage
The Tribute DV is packaged by the manufacturer to
withstand shipment without damage. However,
damage can still occur during transit; so take care to
inspect for damage when unpacking and installing
the unit. If any damage or missing parts are
detected, immediately contact your dealer
.
Do not install, or put into service, a damaged
or incomplete heater.
Inspect the Tribute DV for visible or concealed
damage. The unit should appear to be square and
true. The sheet metal parts should be smooth and
free of bends and dents. The enameled cast iron
should be free of chips or cracks. If visible or
concealed damage is found or suspected, contact
your dealer for instructions.
With the accessory box removed and set aside, take
care not to mar or chip the enameled legs, if
applicable. Have someone help lift the stove out of
the shipping box and set it into place.
The TEK Burner and TEK Fire logs supplied with the
Tribute DV are contained in the accessory box.
Always use great care when handling the decorative
fire logs, as they are fragile and subject to damage
and breakage if handled roughly. If a broken log is
encountered, contact your dealer for replacement
logs. Otherwise, set the logs aside until called for
during the installation.