Hearthstone Quality Home Heating Products, Inc.
Tribute DV Model #8050
12
V
ENTING
I
NFORMATION
V
ENT
C
ONNECTION
1. The Tribute DV Direct Vent is approved for
installation only with the vent connecting
components listed; Simpson Dura-Vent Direct
Vent GS, AmeriVent Direct, Selkirk Direct
Temp™ EXCELDirect or Secure Vent systems.
2. Install the vent system according to the
manufacturer’s instructions.
R
ESTRICTION
P
LATE
There is a vent restriction plate that adjusts the flow
rate of exhaust gases. This insures proper flames
and efficiency for the wide variety of vent
configurations. Controlling the draft also changes
the aesthetics of the flame. The restriction plate
consists of a rotating shutter behind the starter
section of pipe and an adjustment plate with an
index hole used to hold the shutter in a fixed
position. The restriction plate has unlimited settings.
Depending on the vent configuration, you may be
required to adjust the restriction plate position.
For
straight out the back installations no adjustment
to the restrictor is necessary.
A
DJUSTMENT TO
R
ESTRICTION
P
LATE
Make sure the unit is cool before touching any part
of the firebox. To adjust your restrictor for maximum
flame appearance, loosen the Phillips head screw,
found on the upper rear right side of the stove. Spin
the indicator tab into the desired position. Rotating
counterclockwise closes the exhaust gasses, while
rotating clockwise opens the exhaust gases. Once
the desired restriction is reached, tighten the screw.
There are unlimited positions for the restriction plate,
one (1) being the lowest and three (3) being the
highest. (Refer to Venting Configuration –
Figure 4
for recommended restriction plate positions)
NOTE: These positions are based on lab
results and can have some variance.
VENT
PIPE
CLEARANCES
All flue vent pipe for the Tribute DV must be installed
with the following clearances to combustibles.
1” - For vertical pipe
1” - Below and along the side of all horizontal pipes.
2” - On top of all horizontal pipes.
V
ENTING
C
OMPONENTS
&
C
ONFIGURATION
The Tribute DV cannot be vented jointly with any
other solid fuel or gas appliance. It must be vented
directly to the outside of the building using a proper
termination as listed in the manual. The only types of
venting pipe approved for use with your Tribute DV
Direct-Vent stove is Simpson Dura-Vent’s GS,
AmeriVent Direct, Selkirk Direct Temp™
EXCELDirect and Secure Vent Direct-Vent Pipe.
The venting configuration is shown in
Figure 5 (with
the optional snorkel), and Figure 6 showing the
minimum vent kit
. After determining the venting
configuration for your stove, select the vent system
that will accommodate your installation.
CAUTION: ENSURE THERE IS NO WIRING OR
PLUMBING IN THE CHOSEN LOCATION.
CAUTION: DO NOT RECESS VENTING
TERMINALS INTO A WALL OR SIDING.
Note:
If further direction is needed for installation,
please refer to the venting instructions, which are
provided with the venting components.
A
CCEPTABLE
D
IRECT
-V
ENT
T
ERMINATION
C
AP
L
OCATIONS
The vent/air intake termination clearances above the
high side of an angled roof are as follows:
Roof
Pitch
Feet
Meters
Flat to 6/12
1
0.3
7/12 to 9/12
2
0.6
10/12 to 12/12 4
1.2
13/12 to 16/12
6
1.8
17/12 to 21/12 8
2.4
Listed are Simpson Dura-Vent, AmeriVent Direct,
Selkirk Direct Temp™
and Secure Vent
components acceptable for installation, along with
the minimum venting kit available. The venting
system must be comprised of the appropriate
venting components as specified.