background image

Hearthstone Quality Home Heating Products, Inc.                                 

                         Tribute DV Model #8050 

 

 

18

G

AS 

S

UPPLY 

&

 

C

ONNECTIONS

 

 

Figure 8: Gas control valve 

 

WARNING: THE UNIT MUST BE INSTALLED AND 
CONNECTED IN ACCORDANCE WITH LOCAL 
CODES, OR IN THE ABSENCE OF LOCAL CODES, 
WITH THE MOST CURRENT EDITION OF THE 
NATIONAL FUEL GAS CODE ANSI Z223.1 (NFPA 
54) OR CAN/CSA B149 INSTALLATION CODE.  

 

 

NOTICE: A qualified technician must connect the 
heater to the gas supply and leak test the unit 
before it is approved for use. Consult all codes.

 

 

3" MIN.

Cap

Nipple

To Equipment

Inlet

Tee Fitting

Gas Supply

Inlet

 

Figure 9: Typical Sediment Trap 

(Required in all 

installation)

 

 

NFPA Code and Hearthstone require the use of a 
dedicated sediment trap just upstream of the unit. 
Damage to the valve, or other components due to 
the lack of a sediment trap are not covered by 
warranty. 

 
G

AS 

C

ONNECTIONS

 

The gas supply connection is made to the Tribute 
DV’s gas control valve in the middle of the lower rear 
of the stove, using a 3/8” male NPT fitting.  The 
supply line should be ½” diameter, or appropriately 
sized to provide a sufficient gas supply to meet the 
maximum demand of the unit without undue loss of 
pressure. We recommend a flexible line to avoid 
undue mechanical load on the valve and to ease 
thread alignment, but refer to local codes. 
 

 

CAUTION: CHECK GAS TYPE! 

 
G

AS 

S

UPPLY

 

This appliance and its individual shutoff valve must 
be disconnected from the gas supply piping system 
during any pressure testing of that system at test 
pressures in excess of ½ psig. The Tribute DV must 
be isolated from the gas supply piping system by 
closing its individual manual shutoff valve during any 
pressure testing of the gas supply piping system at 
test pressures equal to or greater than ½ psig. 

 

Summary of Contents for Tribute DV 8050

Page 1: ...nstaller service agency or gas supplier must perform installation and service The Commonwealth of Massachusetts requires that a licensed gas fitter or licensed plumber install all gas lines and gas fittings AVERTISSEMENT ASSUREZ VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE D INCENDIE OU POUR ÉVITER TOUT DOMMAGE MATÉERIEL TOUTE BLESSURE OU LA MORT N...

Page 2: ...Hearthstone Quality Home Heating Products Inc Tribute DV Model 8050 2 Intentionally Blank ...

Page 3: ...sary Keep your original receipt in a safe place as proof of purchase Serial Number Fuel type Natural Gas Liquid Propane Sold by Date of Purchase Address Phone E mail Website Installed by Date of Installation Address Phone E mail Website Gas Supplier Address Phone E mail Website Read this Owner s Manual before installing or operating your TRIBUTE Retain this manual for future reference SERVICE RECO...

Page 4: ...EARANCE TO COMBUSTIBLES 10 ACCEPTABLE DIRECT VENT TERMINATION CAP LOCATIONS 11 VENTING INFORMATION 12 VENTING COMPONENTS CONFIGURATION 12 APPROVED VENTING SYSTEM COMPONENTS 14 ELECTRICAL CONNECTIONS 16 WIRING INSTRUCTIONS 17 GAS SUPPLY CONNECTIONS 18 LOG PLACEMENT 20 INSTALLATION OF THE LOG SET 20 REMOVAL OF LOG SET 21 STONE INSTALLATION 22 LIGHTING THE UNIT FOR THE FIRST TIME 23 INITIAL ADJUSTMEN...

Page 5: ... OPERATE THIS APPLIANCE WITH THE GLASS OR ANY PANEL REMOVED CRACKED OR BROKEN DO NOT SUBJECT THE DOOR TO ABUSE SUCH AS STRIKING OR SLAMMING SHUT ONLY A LICENSED OR QUALIFIED SERVICE PERSON SHOULD REPLACE THE GLASS PANEL WHEN NECESSARY Never Burn Paper Wood or Other Materials This gas heater is designed to burn natural gas NG or liquid propane LP Never burn any fuel not intended for use with this u...

Page 6: ...ervice duravent com American Metal Products www americanmetalproducts com vent amerivent htm 1 800 423 4270 info americanmetalproducts com Selkirk Corporation http www selkirkinc com 1 800 992 VENT 8368 sales selkirkinc com custsvc selkirkinc com Security Chimneys International http www securitychimneys This product is manufactured and warranted by Hearthstone Quality Home Heating Products Inc 317...

Page 7: ... Certified for Canada CSA P 4 1 Approved for Mobile Home Installation Figure 1 Tribute DV Dimensions Specification NG LP INPUT RATING Btu hr 0 2000 ft 18 000 17 500 ORIFICE SIZE DMS 0 2000 ft 48 56 ORIFICE SIZE DMS 0 4500 ft 48 56 MANIFOLD PRESSURE LO SETTING in W c kpa 1 2 0 30 3 3 0 82 MANIFOLD PRESSURE HI SETTING in W c kpa 3 5 1 15 10 0 2 48 INLET PRESSURE LO in w c kpa 5 0 1 24 10 0 2 48 MINI...

Page 8: ... wasted When putting the unit back into service follow the lighting instructions described on page 24 CONDENSATION Fuel gasses produce water vapor when burned Therefore when the unit is first lit especially when cool it is normal to experience some condensation on the inside of the window glass This condensation will burn off within the first few minutes of operation If continuous condensation on ...

Page 9: ...y local code Safety Glasses Gloves PACKING LIST 1 Tribute DV Gas Fired Heater 1 TEK Burner 5 Decorative TEK Fire logs 1 Bag Platinum Bright Embers 1 Owner s Manual 1 Thermostat 1 40 Thermostat wire 1 Warranty Validation Form Note Vent kits and components are supplied separately Failure to use the venting components specified by Hearthstone QHHP Inc will void your warranty and could risk a fire UNP...

Page 10: ...ustion chamber and allow for adequate ventilation Minimum clearances to combustibles must be maintained as shown in the illustrations of the Clearances To Combustibles section CAUTION THESE CLEARANCES REPRESENT MINIMUM DISTANCES IN ALL CASES WHICH THROUGH TESTING IN AN INDEPENDENT LABORATORY TO ANSI AND CSA STANDARDS WILL PREVENT FIRE OR SPONTANEOUS COMBUSTION WE DO NOT CONTROL THE COMBUSTIBLE MAT...

Page 11: ...Hearthstone Quality Home Heating Products Inc Tribute DV Model 8050 11 ACCEPTABLE DIRECT VENT TERMINATION CAP LOCATIONS Figure 3 Termination Location clearances ...

Page 12: ...uration Figure 4 for recommended restriction plate positions NOTE These positions are based on lab results and can have some variance VENT PIPE CLEARANCES All flue vent pipe for the Tribute DV must be installed with the following clearances to combustibles 1 For vertical pipe 1 Below and along the side of all horizontal pipes 2 On top of all horizontal pipes VENTING COMPONENTS CONFIGURATION The Tr...

Page 13: ...Hearthstone Quality Home Heating Products Inc Tribute DV Model 8050 13 Figure 4 Venting Restrictor configurations ...

Page 14: ...ling Support Wall Thimble Covers Wall thimble CHIMNEY LINER SYSTEM 1 Direct Vent Chimney Liner Termination Kit 2 Chimney Liner Flex 3 Co Linear Flex Connector 4 Co Axial to Co Linear Appliance Connect MINIMUM VENT KIT 6 Straight Wall Thimble Cover optional Wall Thimble Horizontal Vent Cap wall thimble wall thimble cover 14 snorkel You must have a 1 4 of rise per horizontal foot of venting Dependin...

Page 15: ...s not provided Install the exterior portion of the thimble in similar fashion overlapping the 2 sections CAUTION FOR BUILDINGS WITH VINYL SIDING A VINYL SIDING STANDOFF SHOULD BE INSTALLED BETWEEN THE VENT CAP AND THE EXTERIOR WALL 5 Install the horizontal vent termination on the outside of the wall Make sure both of the retaining straps extend through interior wall thimble Before attaching the ve...

Page 16: ...y 5 1 5m off the floor and away from any influences that may cause the temperature in the vicinity of the thermostat to be unrepresentative of the room temperature in general Such influences might include strong lighting a heater vent from the central heating system or a nearby drafty window Placement of the thermostat on an inside wall rather than an outside wall is preferable Do not place the th...

Page 17: ...ATION AFTER SERVICING ATTENTION AU MOMENT DE L ENTRETIEN DES COMMANDES ÉTIQUETEZ TOUS LES FILS AVANT LE DÉBRANCHEMENT DES ERREURS DE CÂBLAGE PEUVENT ENTRAÎNER UN FONCTIONNEMENT INADEQUAT ET DANGERUX THE PROPER LOCATION OF WIRE CONNECTIONS IS SHOWN IN FIGURE 7 Y V Bk Bk Bk Wiring Color KEY Hearthstone 10 20 30 50 70 90 c OFF O YG Bk V Y 10 20 30 c 50 60 70 80 90 O G R Bk Br B W Wiring Diagram Tribu...

Page 18: ...nts due to the lack of a sediment trap are not covered by warranty GAS CONNECTIONS The gas supply connection is made to the Tribute DV s gas control valve in the middle of the lower rear of the stove using a 3 8 male NPT fitting The supply line should be diameter or appropriately sized to provide a sufficient gas supply to meet the maximum demand of the unit without undue loss of pressure We recom...

Page 19: ...s must be tested The supply line pressure is tested to insure it meets the minimum gas supply pressure as listed in the Specifications for the type of fuel in use natural gas or LP by connecting a manometer to the supply line and adjusting the incoming pressure if necessary to meet the required supply line pressure as listed in specifications The manifold pressure tap on the gas control valve refe...

Page 20: ...ont grasp both sides of the front cast facade and lift upward and then outward Set the front aside taking care not to chip or scratch the enamel Next locate the two rotating clips above the glass Rotate the clips out of the locked position and tilt the top of the glass outward Lift the entire glass assembly up and out 2 Remove the packaging material around the log set assembly Be careful not to da...

Page 21: ...DV Model 8050 21 REMOVAL OF LOG SET CAUTION THE FIRELOG SET RETAINS HEAT AND CAN BE VERY HOT ALLOW 2 TO 3 HOURS AFTER PILOT LIGHT IS TURNED OFF BEFORE HANDLING To remove the Fire log set follow the Installation of Log Set instructions in the reverse order ...

Page 22: ...ing up taking care not to chip the edges 3 Note the steel side stone clips heat shields already in place used to retain the side stones 4 Slide the side stones 7 3 4 x 10 3 4 down in front of the heat shields through the slots in the top with the polished side facing out To avoid scratching and to make sliding easier ensure you keep the stones back from the corner braces as you slide them down Ins...

Page 23: ...on located next to the gas control valve behind the valve access door which ignites the pilot light by means of a spark at the pilot light assembly Do not attempt to light the unit with a match or by any means other than the piezoelectric spark DO NOT LIGHT PILOT OR BURNER BY HAND The standing pilot light on this gas heater is lit by using a piezoelectric spark generator as described elsewhere in ...

Page 24: ... cover of this Manual If you do not smell gas proceed to the next step 5 Turn gas control knob counter clockwise to PILOT 6 Push in control knob all the way and hold in Immediately light the pilot with the gas lighter push in and click the piezoelectric spark igniter button several times until lit Continue to hold the control knob in for about 20 seconds after the pilot is lit Release the knob and...

Page 25: ...o far Some conditions cannot be corrected through air shutter adjustment an adjustment must be made to the gas supply pressure or by changing the restriction plate location Qualified service personnel must perform supply line manifold gas line pressure adjustments and restrictor plate adjustments Do not attempt to complete any part of the installation or adjustment of this unit unless technically ...

Page 26: ...ner flame should be performed The burner flames can be adjusted by means of the air shutter To determine if the burner flame needs adjustment it is necessary to view the flame pattern with the variable output control knob at its highest setting turn fully clockwise Allow the unit to operate for 10 minutes enabling the entire unit to reach temperature and for the flame pattern to stabilize The flam...

Page 27: ... decorative logs out of the firebox re install the glass assembly and front cast Briefly light the unit according to the lighting instructions described on page 22 Check to insure a proper flame is burning from each burner port The pilot flame should be large enough to engulf the thermopile and thermocouple as shown in Figure 10 NOTE Do not operate the unit for more than 1 2 minutes without the lo...

Page 28: ...mpurities it will be necessary to clean the inside of the glass occasionally Do not use abrasive cleaners Scratching the glass will weaken the integrity of the glass Do not clean the glass when hot Allow the glass to cool and apply a mild window cleaning fluid Special gas appliance window cleaner is available from your local Hearthstone dealer WARNING DO NOT OPERATE THIS APPLIANCE WITH THE GLASS P...

Page 29: ...LABEL 7211 370 BURNER PILOT CON TOP 3 WAY NG 199 724 3300 581 FUEL CONVERSION LABEL 7211 407 KNOB EXTENSION CONTROL 1 ON OFF SIT 5050 005 VALVE BRACKET 7211 404 KNOB EXTENSION CONTROL 1 HI LO SIT 0916218 5050 010 FIREBOX 7211 027 3 8 X 6 SS FLEX TUBE STG TUDOR 5050 015 SHUTTER 7210 008 FITTING 90deg 3 8 NPTx3 8 CMP NUT FER 5050 017 SHUTTER BOX 7211 003 FITTING STRAIGHT 1 4 NPT x 3 8 COMP 5050 020 ...

Page 30: ...nsulation If properly connected and no spark replace igniter E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas pressure B Faulty connections C Defective thermocouple D Pilot dirty or plugged A Check for proper inlet pressure for the gas being used B Measure voltage between valve body and solder connection on the re...

Page 31: ...n or replace Note do not use any metal cleaning device as this may damage the orifice 4 Pilot and burner come on but go out after some warm up A Inconsistent or insufficient flame on thermopile B Insufficient gas pressure C Excessive draft A Adjust pilot flame size and assure that the flame is aimed directly at the thermopile B Check line pressure to ensure that the correct inlet pressure is prese...

Page 32: ...structions B3 Clear obstructions C If gas pressures are correct and the flames stay the same adjust the air shutter for a proper burn 9 Burner flashback Air gas mixture ignites inside the burner near the orifice usually creating a roaring noise like a blowtorch The problem is an imbalance of gas flow velocity and burning speed pattern A Excessive primary air B Burner input underrated C Valve leak ...

Page 33: ... Oct Nov Dec DO NOT REMOVE OR COVER THIS LABEL MADE IN USA 3300 580 FUEL TYPE Several Optional kits are available through HearthStone or your local HearthStone dealer A blower assembly may be used two different remote controls kit 90 56912 kit 90 56914 and an optional viewing screen is also available 90 69500 kit 90 57501 101001 DO NOT OPERATE WITH GLASS REMOVED OR BROKEN This appliance must be in...

Page 34: ...Hearthstone Quality Home Heating Products Inc Tribute DV Model 8050 34 ...

Page 35: ...onestoves com or send a completed and signed Warranty Registration Form which is enclosed in the Gas Stove warranty packet to the following address Hearthstone Quality Home Heating Products Inc Warranty Department 317 Stafford Avenue Morrisville VT 05661 NOTE SENDING IN THE SIGNED WARRANTY REGISTRATION FORM IS NOT REQUIRED AS A CONDITION OF WARRANTY COVERAGE OR HEARTHSTONE S PERFORMANCE ...

Page 36: ...Hearthstone Quality Home Heating Products Inc Tribute DV Model 8050 36 Notes ...

Reviews: