Hearthstone Quality Home Heating Products, Inc.
Tribute DV Model #8050
7
S
PECIFICATIONS
L
ISTED AS
:
Gas-Fired Direct-Vent Fireplace Heater
Model:
Tribute DV Model 8050 Direct-Vent Gas
Fireplace Heater
Testing Agency:
Intertek Testing Services, Inc.
Tested to:
ANSI Z21.88b – 2008/CSA 2.33b - 2008
Certified for Canada, CSA P.4.1
Approved for Mobile Home Installation
Figure 1: Tribute DV Dimensions
Specification
NG LP
INPUT RATING (Btu/hr) 0-2000 ft
18,000 17,500
ORIFICE SIZE (DMS) 0-2000 ft
48 56
ORIFICE SIZE (DMS) 0-4500 ft
48 56
MANIFOLD PRESSURE - LO SETTING (in. W.c./kpa)
1.2/0.30 3.3/0.82
MANIFOLD PRESSURE - HI SETTING (in. W.c./kpa)
3.5/1.15 10.0/2.48
INLET PRESSURE - LO (in.w.c./kpa)
5.0/1.24 10.0/2.48
MINIMUM INPUT RATING (btu/hr)
10,600 10,400
MAXIMUM OUTPUT (btu/hr) 0-2000 ft
13,300 13,200