C

LEARANCE TO 

C

OMBUSTIBLES

 

Due to high surface temperatures, the unit 
should be located out of traffic and away 
from furniture and draperies. Clothing and 
other flammable material should not be 
placed on or near the heater. When 
positioning the unit always maintain 
adequate clearances around air openings into 
the combustion chamber and allow for 
adequate ventilation. Minimum clearances 
to combustibles must be maintained as 
shown in the illustrations in figures 4-7.  

Note: The rear clearance to combustibles 
will be determined by either the unit’s or the 
vent pipe’s minimum clearance, (A refer to 
Figures 6+7) depending on whether the 
installation calls for vertical rise within the 
room or a rear exit, through-the-wall vent 
pipe. 

Be sure to consider the need for access to 
the gas control valve access door on the 
front of the unit as well as full access for 
periodic cleaning and servicing. Also 
consider the location of the Optional Blower 
Fan. 

NOTE: These clearances represent 

minimum 

distances in all cases, which, through testing in an 
independent laboratory to ANSI and CSA 
standards, will prevent fire or spontaneous 
combustion. We do not control the combustible 
materials exposed to heat by this product; 
therefore, an assessment must be made by the 
installer to prevent consequential damage of walls 
and flooring. 

2.00

2.00

14-1/2"

10-1/4"

 

Figure 4: Corner Clearances to Combustibles 

12-1/2"

6"

2.00

2.00

 

Figure 5: Minimum Wall Clearance To 
Combustibles

Summary of Contents for Tucson (8700)

Page 1: ...fire department A qualified installer service agency or gas supplier must perform installation and service AVERTISSEMENT Assurez vous de bien suivre les instructions donn dans cette notice pour r dui...

Page 2: ...ims if necessary Keep your original receipt in a safe place as proof of purchase Serial Number Fuel type check one Natural Gas Liquid Propane Sold by Phone Date of Purchase Installed by Phone Date of...

Page 3: ...the optional thermostat has been installed and the On Off T stat switch is set to T stat the wall mounted thermostat will control the on off cycling of the unit At any time you can override the therm...

Page 4: ...o smoke turn the heater off and call a qualified service technician The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of...

Page 5: ...the accumulation of dust and lint NEVER BURN PAPER WOOD OR OTHER MATERIALS This gas heater is designed to burn natural gas or liquid propane LP Never burn any fuel not intended for use with this unit...

Page 6: ...by using a piezoelectric spark generator as described elsewhere in this manual Never attempt to light the pilot or main burners by hand with a match or lighter If after repeated attempts the pilot li...

Page 7: ...qu s sur la plaque signal tique Ne pas l utiliser avec d autres gas sauf si un kited conversion certifi est install SERVICE CAUTION Any shield door or safety screen component removed for servicing wil...

Page 8: ...21 88 2002 CSA 2 33 M02 CAN CGA2 17 M91 Certified for Canada Approved for Mobile Home Installation see page 7 Figure 1 Tucson Dimensions NG LP Input rating Btu hr 0 1370 m 26 000 26 000 Maximum output...

Page 9: ...When putting the unit back into service follow the lighting instructions described on page 24 When the unit is first lit especially when cool it is normal to experience some condensation on the inside...

Page 10: ...ng the thermostat to OFF and turning off the gas control valve Allow the unit to cool Check and clean any burner ports that are not burning or not burning properly Clean burner ports using soft a soft...

Page 11: ...nd mark the spot to be cut 4 Cut the gasket at the marked spot with a utility knife Twist the ends slightly to prevent the gasket from unraveling 5 Apply water glass adhesive to the gasket channel 6 S...

Page 12: ...ufactured Home Installation ANSI NCBCS A225 1 or Standard for Gas Equipped Recreational Vehicles and mobile Housing CSA Z240 4 CAN SCA Z240 MH Canada Installer l appareil selon les codes ou r glements...

Page 13: ...f visible or concealed damage is found or suspected contact your dealer for instructions With the top grill removed and set aside undo the lag bolts that fasten the unit to the pallet Take care not to...

Page 14: ...r to Figures 6 7 depending on whether the installation calls for vertical rise within the room or a rear exit through the wall vent pipe Be sure to consider the need for access to the gas control valv...

Page 15: ...roperly connected to a 4 102 mm diameter type B 1 vent which is constructed and installed in accordance with NFPA54 and NFPA211 Single wall vent pipe may be used within the same room as the Tucson so...

Page 16: ...t The Tucson cannot and must not be connected to an outside air source the unit must take its combustion air from the living space in which it is installed The draft hood is equipped with a safety shu...

Page 17: ...devices prevents operation of the heater unless the power vent is operating properly Both the Tucson and the power vent are controlled by the wall thermostat and neither will operate if there is a pow...

Page 18: ...nd away from any influences that may cause the temperature in the vicinity of the thermostat to be unrepresentative of the room temperature in general Such influences might include strong lighting a h...

Page 19: ...servicing Attention Au moment de l entretien des commandes tiquetez tous les fils avant le d branchement Des erreurs de c blage peuvent entra un fonctionnement inadequate et dangereux The proper loca...

Page 20: ...gas control valve just inside the left front leg of the unit using a 3 8 male NPT fitting The supply line should be diameter or appropriately sized to provide a sufficient gas supply to meet the maxi...

Page 21: ...in order to obtain a pleasing flame pattern and efficient combustion Incorrect log placement may cause carbon build up excess thermal stress on the log set and stove parts reduced efficiency and high...

Page 22: ...HearthStone Quality Home Heating Products Inc Tucson Model 8700 22 Figure ll Log Set...

Page 23: ...water based polishing system prior to the assembly of the unit Any residue moisture in the stones must be dried out slowly to avoid damaging the stones This is accomplished by adhering to the followi...

Page 24: ...And Gas Supply and Connections sections of this manual the unit is almost ready to be lit for the first time The manufacturer tests each unit prior to shipment so ignition should take place without fa...

Page 25: ...e thermostat or the on off switch located on the bottom of the thermostat body NOTE When pressing clicking the piezoelectric spark ignition button to light the pilot watch through the glass front of t...

Page 26: ...if the burner flame needs adjustment it is necessary to view the flame pattern with the variable output control knob at its highest setting turn fully clockwise Allow the unit to operate for 10 minut...

Page 27: ...erature and for the flame pattern to stabilize Generally the more air open shutter in the mixture the bluer the flame Less air closed shutter results in a more yellow flame but too little air will res...

Page 28: ...et 93 56201 LP Conversion Kit 5710 180 Door Latch Bracket 7200 240 Burner Orifice NG 40 2710 560 Glass Ret Frame 7200 253 Burner Orifice LP 53 2710 581 Front Grill 7211 370 Pilot Burner Assembly 2710...

Page 29: ...insulation If properly connected and no spark replace ignitor E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas pre...

Page 30: ...er does not come on replace the gas valve C Remove and check burner orifice clean or replace Note do not use any metal cleaning device as this may damage the orifice 4 Pilot and burner come on but go...

Page 31: ...B2 Clear obstructions B3 Clear obstructions C If gas pressures are correct and the flames stay the same adjust the air shutter for a proper burn 9 Burner flashback Air gas mixture ignites inside the b...

Page 32: ...box and firebox baffle against breakage cracking or burn through Convective heat exchanger against breakage cracking or burn through Burners air shutters and orifices against breakage cracking or burn...

Page 33: ...OR REMEDIES IN CONTRACT OR TORT WHETHER OR NOT ARISING FROM HEARTHSTONE S NEGLIGENCE ACTUAL OR IMPUTED ALL IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR...

Page 34: ...r parts Within the first ninety 90 days after the Purchase Date HearthStone will pay for the shipping of Stove parts covered by any of the foregoing warranties to and from HearthStone or a Dealer as t...