background image

HearthStone Quality Home Heating Products Inc

                                                                   Tucson 

Model #8700

 

 

4

T

ABLE OF 

C

ONTENTS

 

READ THIS OWNER’S MANUAL........ 1

 

I

NTRODUCTION

........................................... 3

 

S

AFETY 

I

NFORMATION

............................... 4

 

SPECIFICATIONS: ................................. 8

 

O

WNER

I

NFORMATION

............................ 9

 

R

OUTINE 

M

AINTENANCE AND 

C

ARE

......... 9

 

I

NSTALLER

I

NFORMATION

.................... 12

 

U

NPACK AND 

I

NSPECT FOR 

D

AMAGE

..... 13 

E

LECTRICAL 

C

ONNECTIONS

.................... 18

 

G

AS 

S

UPPLY 

& C

ONNECTIONS

................. 20

 

L

OG 

P

LACEMENT

..................................... 21

 

I

NITIAL 

A

DJUSTMENTS

............................. 24

 

P

ARTS 

L

ISTS

............................................. 28

 

 

 

S

AFETY 

I

NFORMATION

 

 

Your Tucson is a very attractive and 
extremely efficient, utilizing today’s best 
technologies. By following a few simple 
safety precautions and by performing minimal 
maintenance, the unit will remain appealing 
while providing years of quality performance. 
 
The installation must conform to local codes 
or, in the absences of local codes, the current 
National Fuel Gas Code, ANSI Z223.1 (NFPA 
54) or CAN/CGA B149 Installation Code. 
(

Installer l’appareil selon les codes ou 

réglements locaux, ou, en l’absence de tells 
réglements, selon les Codes d’installation 
CAN/CGA B149

.) 

 
During the first few hours of operation the 
appliance may produce a slight smoke and/or 
odor. This is normal during the first several 
burns. During the initial burn, open a 
window(s) to assist in the removal of the 

smoke/odor. If the logs appear to smoke, turn 
the heater off and call a qualified service 
technician. 
The appliance and its individual shutoff valve 
must be disconnected from the gas supply 
piping system during any pressure testing of 
that system at test pressures in excess of ½ 
psig. (3.5k Pa). The appliance must be isolated 
from the gas supply piping system by closing 
its individual manual shutoff valve during any 
pressure testing of the gas supply piping 
system at test pressures equal to or less than ½ 
psig (3.5k Pa). 
 

F

IRE 

H

AZARD

 

Do not store or use gasoline or other 
flammable vapors or liquids in the vicinity 
of this appliance. The Tucson should be 
located out of traffic and away from 
furniture, draperies, clothing, and flammable 
material. 

 

S

HOCK  

H

AZARD 

 

(When equipped with an optional blower) 

This appliance is equipped with a three-prong 
(grounding) plug for protection against shock 
hazard and should be plugged directly into a 
properly grounded three-prong receptacle.  Do 
not cut or remove the grounding prong from the 
plug. 

 

M

UST BE 

V

ENTED TO THE 

O

UTSIDE

 

Never vent the gas heater to other rooms or 
buildings. This gas appliance must not be 
connected to a chimney flue serving a 
separate solid-fuel burning appliance. 

 

S

ERVICE 

C

AUTION

 

If you believe your Tucson is not, in any 
way, performing properly, immediately 
discontinue operation until the unit has been 
inspected and approved by qualified service 
personnel.  Prior to servicing the unit, turn 

Summary of Contents for Tucson (8700)

Page 1: ...fire department A qualified installer service agency or gas supplier must perform installation and service AVERTISSEMENT Assurez vous de bien suivre les instructions donn dans cette notice pour r dui...

Page 2: ...ims if necessary Keep your original receipt in a safe place as proof of purchase Serial Number Fuel type check one Natural Gas Liquid Propane Sold by Phone Date of Purchase Installed by Phone Date of...

Page 3: ...the optional thermostat has been installed and the On Off T stat switch is set to T stat the wall mounted thermostat will control the on off cycling of the unit At any time you can override the therm...

Page 4: ...o smoke turn the heater off and call a qualified service technician The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of...

Page 5: ...the accumulation of dust and lint NEVER BURN PAPER WOOD OR OTHER MATERIALS This gas heater is designed to burn natural gas or liquid propane LP Never burn any fuel not intended for use with this unit...

Page 6: ...by using a piezoelectric spark generator as described elsewhere in this manual Never attempt to light the pilot or main burners by hand with a match or lighter If after repeated attempts the pilot li...

Page 7: ...qu s sur la plaque signal tique Ne pas l utiliser avec d autres gas sauf si un kited conversion certifi est install SERVICE CAUTION Any shield door or safety screen component removed for servicing wil...

Page 8: ...21 88 2002 CSA 2 33 M02 CAN CGA2 17 M91 Certified for Canada Approved for Mobile Home Installation see page 7 Figure 1 Tucson Dimensions NG LP Input rating Btu hr 0 1370 m 26 000 26 000 Maximum output...

Page 9: ...When putting the unit back into service follow the lighting instructions described on page 24 When the unit is first lit especially when cool it is normal to experience some condensation on the inside...

Page 10: ...ng the thermostat to OFF and turning off the gas control valve Allow the unit to cool Check and clean any burner ports that are not burning or not burning properly Clean burner ports using soft a soft...

Page 11: ...nd mark the spot to be cut 4 Cut the gasket at the marked spot with a utility knife Twist the ends slightly to prevent the gasket from unraveling 5 Apply water glass adhesive to the gasket channel 6 S...

Page 12: ...ufactured Home Installation ANSI NCBCS A225 1 or Standard for Gas Equipped Recreational Vehicles and mobile Housing CSA Z240 4 CAN SCA Z240 MH Canada Installer l appareil selon les codes ou r glements...

Page 13: ...f visible or concealed damage is found or suspected contact your dealer for instructions With the top grill removed and set aside undo the lag bolts that fasten the unit to the pallet Take care not to...

Page 14: ...r to Figures 6 7 depending on whether the installation calls for vertical rise within the room or a rear exit through the wall vent pipe Be sure to consider the need for access to the gas control valv...

Page 15: ...roperly connected to a 4 102 mm diameter type B 1 vent which is constructed and installed in accordance with NFPA54 and NFPA211 Single wall vent pipe may be used within the same room as the Tucson so...

Page 16: ...t The Tucson cannot and must not be connected to an outside air source the unit must take its combustion air from the living space in which it is installed The draft hood is equipped with a safety shu...

Page 17: ...devices prevents operation of the heater unless the power vent is operating properly Both the Tucson and the power vent are controlled by the wall thermostat and neither will operate if there is a pow...

Page 18: ...nd away from any influences that may cause the temperature in the vicinity of the thermostat to be unrepresentative of the room temperature in general Such influences might include strong lighting a h...

Page 19: ...servicing Attention Au moment de l entretien des commandes tiquetez tous les fils avant le d branchement Des erreurs de c blage peuvent entra un fonctionnement inadequate et dangereux The proper loca...

Page 20: ...gas control valve just inside the left front leg of the unit using a 3 8 male NPT fitting The supply line should be diameter or appropriately sized to provide a sufficient gas supply to meet the maxi...

Page 21: ...in order to obtain a pleasing flame pattern and efficient combustion Incorrect log placement may cause carbon build up excess thermal stress on the log set and stove parts reduced efficiency and high...

Page 22: ...HearthStone Quality Home Heating Products Inc Tucson Model 8700 22 Figure ll Log Set...

Page 23: ...water based polishing system prior to the assembly of the unit Any residue moisture in the stones must be dried out slowly to avoid damaging the stones This is accomplished by adhering to the followi...

Page 24: ...And Gas Supply and Connections sections of this manual the unit is almost ready to be lit for the first time The manufacturer tests each unit prior to shipment so ignition should take place without fa...

Page 25: ...e thermostat or the on off switch located on the bottom of the thermostat body NOTE When pressing clicking the piezoelectric spark ignition button to light the pilot watch through the glass front of t...

Page 26: ...if the burner flame needs adjustment it is necessary to view the flame pattern with the variable output control knob at its highest setting turn fully clockwise Allow the unit to operate for 10 minut...

Page 27: ...erature and for the flame pattern to stabilize Generally the more air open shutter in the mixture the bluer the flame Less air closed shutter results in a more yellow flame but too little air will res...

Page 28: ...et 93 56201 LP Conversion Kit 5710 180 Door Latch Bracket 7200 240 Burner Orifice NG 40 2710 560 Glass Ret Frame 7200 253 Burner Orifice LP 53 2710 581 Front Grill 7211 370 Pilot Burner Assembly 2710...

Page 29: ...insulation If properly connected and no spark replace ignitor E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas pre...

Page 30: ...er does not come on replace the gas valve C Remove and check burner orifice clean or replace Note do not use any metal cleaning device as this may damage the orifice 4 Pilot and burner come on but go...

Page 31: ...B2 Clear obstructions B3 Clear obstructions C If gas pressures are correct and the flames stay the same adjust the air shutter for a proper burn 9 Burner flashback Air gas mixture ignites inside the b...

Page 32: ...box and firebox baffle against breakage cracking or burn through Convective heat exchanger against breakage cracking or burn through Burners air shutters and orifices against breakage cracking or burn...

Page 33: ...OR REMEDIES IN CONTRACT OR TORT WHETHER OR NOT ARISING FROM HEARTHSTONE S NEGLIGENCE ACTUAL OR IMPUTED ALL IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR...

Page 34: ...r parts Within the first ninety 90 days after the Purchase Date HearthStone will pay for the shipping of Stove parts covered by any of the foregoing warranties to and from HearthStone or a Dealer as t...