HearthStone Quality Home Heating Products Inc
Tucson
Model #8700
8
SPECIFICATIONS:
L
ISTED
:
B-V
ENT
G
AS
H
EATER
Listed:
Gas-Fired B-Vent Fireplace Heater
Model:
Tucson B-Vent Gas Fireplace Heater
Testing Agency:
Intertek Testing Services NA Inc. (ITS)
Tested to:
ANSI Z21.88-2002, CSA 2.33-M02, CAN/CGA2.17-M91
Certified for Canada
Approved for
Mobile Home Installation (see page 7)
Figure 1: Tucson Dimensions
NG
LP
Input rating (Btu/hr) 0-1370 m
26,000 26,000
Maximum output (Btu/hr) 0-1370 m
20,000 20,500
Minimum input rating (Btu/hr)
14,700 14,700
Orifice size DMS 0-1370 m
40
53
Man. pressure- HI setting (in.w.c./kPa)
3.5/0.9 10.0/2.5
Man. pressure- LO setting (in.w.c./kPa)
1.2/0.3
3.3/0.8
Inlet pressure-Lo (in.w.c./kPa)
5.0/1.25 11.0/2.75