background image

Hearthstone Quality Home Heating Products, Inc.                               

    TUDOR 8120 Gas-Fired Direct-Vent                                   

L

IGHTING THE 

U

NIT FOR THE 

F

IRST 

T

IME

 

 

 

WARNING: IF YOU DO NOT FOLLOW THESE 
INSTRUCTIONS EXACTLY, A FIRE OR 
EXPLOSION MAY RESULT CAUSING PROPERTY 
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. 

 

 

CAUTION: LIGHTING THE TUDOR FOR THE FIRST 
TIME AND ADJUSTMENTS TO THE UNIT SHOULD 
BE PERFORMED BY QUALIFIED SERVICE 
PERSONNEL. 

 
This appliance is only for use with the type(s) of gas 
indicated on the rating plate. This appliance is not 
convertible for use with other gases, unless a 
certified kit is used. 

 

Cet appareil doit être atilisé uniquement avec les 
types de gas indiqués sur la plaque signalétique. Ne 
pas l’utiliser avec d’autres gas sauf si un kited 
conversion certifié est installé.  

 

S

MOKE AND 

F

UMES 

W

ARNING

 

When lit for the first time, the Tudor will emit some 
smoke and fumes.  This is normal “off-gassing” of 
the paints and oils used in the manufacturing and 
assembly of the unit.  Open windows to vent the 
room if necessary. The off gassing and fumes will 
subside after the first 10 to 20 minutes of operation. 
 

O

DORS AND 

I

MPURITIES

 

A heater of this type may produce odors during 
heater operation due to impurities that may exist in 
the immediate area. Sources of impurities can be 
cleaning solvents, paint solvents, cigarettes, 
candles, smoke, pet hair, dust, adhesives, new 
carpet, and/or textiles. Such odors will dissipate. 
However, opening a window or otherwise providing 
additional ventilation to the area can alleviate the 
condition. If any odor persists, contact your dealer or 
an authorized service technician. 
 

P

ILOT 

L

IGHT 

W

ARNING

 

The Tudor has a piezoelectric spark igniter (the red 
push button located next to the gas control valve 
behind the valve access door), which ignites the pilot 
light by means of a spark at the pilot light assembly. 

Do not attempt to light the unit with a match or by 
any means other than the piezoelectric spark. 
 

D

N

OT 

L

IGHT 

P

ILOT OR 

TEK

 

B

URNER 

B

H

AND

 

The standing pilot light on this gas heater is lit by 
using a piezoelectric spark generator as described 
elsewhere in this manual. Never attempt to light the 
pilot or main burner by hand with a match or lighter. 
If, after repeated attempts, the pilot light fails to light, 
discontinue operation; turn off the gas at the gas 
control valve, and immediately contact qualified 
service personnel for assistance. 
 

P

REPARE 

F

OR 

L

IGHTING

 

Prepare for the lighting procedure by adjusting the 
thermostat (if equipped) to its lowest setting or OFF 
position. If the gas control knob is not in the OFF 
position, turn the knob fully clockwise to OFF. Locate 
the variable output control knob and turn it fully 
clockwise to the highest setting. 
 
Prior to lighting the unit for the first time, wait 5 
minutes to allow any residual gas within the unit to 
dissipate. Smell all around the appliance area for 
gas. Be sure to smell next to the floor because some 
gases are heavier than air and will settle on the 
floor. If you do not smell gas after this five-minute 
period, proceed with the lighting procedure. If you do 
smell gas, DO NOT proceed with the lighting 
procedure. Instead, 

immediately refer to the What 

To Do If You Smell Gas Warning, on the cover of 
this manual. 

 

 

WARNING: THE VALVE CONTROL HAS AN 
INTERLOCK DEVICE. AFTER SHUTTING OFF ALL 
GAS FLOW, THE PILOT BURNER CANNOT BE 
RELIT UNTIL THE THERMOCOUPLE HAS 
COOLED, ALLOWING THE ELECTROMAGNET TO 
BE RELEASED (APPROX. 60 SECONDS). THE 
GAS CONTROL KNOB IS DESIGNED TO 
OPERATE BY HAND. DO NOT USE ANY TOOLS 
DURING THIS OPERATION. DAMAGED KNOBS 
MAY RESULT IN SERIOUS INJURY. 

 

 

 

 

23

Summary of Contents for Tudor 8120

Page 1: ...ervice agency or gas supplier must perform installation and service In the Commonwealth of Massachusetts all installation of gas lines and gas fitting must be done by a licensed gas fitter or licensed...

Page 2: ...Hearthstone Quality Home Heating Products Inc Tudor Model 8120 2...

Page 3: ...p your original receipt in a safe place as proof of purchase Serial Number Fuel type check one Natural Gas Liquid Propane Sold by Phone Date of Purchase Installed by Phone Date of Installation Gas Sup...

Page 4: ...S 16 REMOTE CONTROL 16 THERMOSTAT WIRING 16 WIRING SCHEMATIC 17 GAS SUPPLY CONNECTIONS 19 GAS CONNECTIONS 19 GAS SUPPLY 19 GAS PRESSURE ADJUSTMENT 19 REFRACTORY PANEL INSTALLATION 20 PANEL PLACEMENT 2...

Page 5: ...OR SLAMMING SHUT REPLACEMENT OF THE GLASS PANEL SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON Replace any shield door or safety screen component removed for servicing prior to operating th...

Page 6: ...3 M02 CAN CGA2 17 M91 Certified for Canada CSA P 4 1 Approved for Mobile Home Installation Figure 1 Tudor Dimensions FUEL TYPE NG LP INPUT RATING Btu hr 0 2000 ft 11 500 11 200 ORIFICE SIZE DMS 0 2000...

Page 7: ...he homeowner can select the optimum flame size for their setting and application During the summer non heating season switch the wall thermostat to OFF and turn off the pilot This will improve the ove...

Page 8: ...nts are supplied separately Failure to use the venting components specified by Hearthstone QHHP Inc will void your warranty and could risk a fire UNPACKING AND INSPECTION Unpack and Inspect for Damage...

Page 9: ...ved prior to any other connections have been made Once removed lift the unit off the legs and set in the desired location CLEARANCE TO COMBUSTIBLES Due to high surface temperatures locate the unit out...

Page 10: ...ality Home Heating Products Inc Tudor Model 8120 6 straight Minumum Venting Components Rear wall clearance 0 Termination cap Wall pass through Insulation blanket Mantle clearance Figure 3 Minimum vent...

Page 11: ...Hearthstone Quality Home Heating Products Inc Tudor Model 8120 Acceptable Direct Vent TERMINATION CAP LOCATIONS Figure 4 Termination clearances 11...

Page 12: ...lable Controlling the draft also changes the aesthetics of the flame The restriction plate consists of a rotating shutter behind the starter section of pipe and an adjustment plate with an index hole...

Page 13: ...Hearthstone Quality Home Heating Products Inc Tudor Model 8120 Figure 6 Venting configurations 13...

Page 14: ...tallations 90 0 Elbow 45 0 Elbow 6 Straight 9 Straight Simpson only 12 Straight 24 Straight 36 Straight 48 Straight 11 14 5 8 Adjustable Pipe Length Horizontal Vent Cap Vertical Vent Cap 14 Snorkel Vi...

Page 15: ...t using the straps from the horizontal vent termination to the interior 6 pipe with 2 sheet metal screws keeping the screws close to the wall thimble as possible Bend or cut the excess strapping so th...

Page 16: ...5m off the floor and away from any influences that may cause the temperature in the vicinity of the thermostat to be unrepresentative of the room temperature in general Such influences might include s...

Page 17: ...RATION AFTER SERVICING ATTENTION AU MOMENT DE L ENTRETIEN DES COMMANDES TIQUETEZ TOUS LES FILS AVANT LE D BRANCHEMENT DES ERREURS DE C BLAGE PEUVENT ENTRA UN FONCTIONNEMENT INADEQUATE ET DANGEREUX THE...

Page 18: ...Hearthstone Quality Home Heating Products Inc Tudor Model 8120 18 Figure 10 Gas control valve...

Page 19: ...gas supply to meet the maximum demand of the unit without undue loss of pressure We recommend a flexible line to avoid undue mechanical load on the valve and to ease thread alignment but refer to loc...

Page 20: ...and inspect for damage or missing parts Contact your dealer if necessary 5 The panels are very fragile do not force them into position 6 Insert the rear panel into the firebox right edge first rotate...

Page 21: ...the front grasp both sides of the front cast facade and lift upward and then outward Set the front aside taking care not to chip or scratch the enamel Next locate the two rotating clips above the glas...

Page 22: ...cast by sliding the upper portion onto the lip of the top and tilting the bottom in flush with the glass assembly It should fit snuggly in place Ensure the glass assembly is properly secured to the f...

Page 23: ...xt to the gas control valve behind the valve access door which ignites the pilot light by means of a spark at the pilot light assembly Do not attempt to light the unit with a match or by any means oth...

Page 24: ...old in Immediately light the pilot with the gas lighter push in and click the piezoelectric spark igniter button several times until lit Continue to hold the control knob in for about 20 seconds after...

Page 25: ...must perform supply line manifold gas line pressure adjustments and restrictor plate adjustments Do not attempt to complete any part of the installation or adjustment of this unit unless technically...

Page 26: ...burner flame should be performed The burner flames can be adjusted by means of the air shutter To determine if the burner flame needs adjustment it is necessary to view the flame pattern with the var...

Page 27: ...ccording to the lighting instructions described on page 22 Check to insure a proper flame is burning from each burner port The pilot flame should be large enough to engulf the thermopile and thermocou...

Page 28: ...will weaken the integrity of the glass Do not clean the glass when hot Allow the glass to cool and apply a mild window cleaning fluid Special gas appliance window cleaner is available from your local...

Page 29: ...3120 140 interior top 3120 141 interior left 3120 142 interior right 3120 143 interior rear 3120 125 heatshield top 7211 536 Ember bed 7211 537 rear log 7211 538 front log ELECTRICAL 7000 014 Thermost...

Page 30: ...insulation If properly connected and no spark replace igniter E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas pres...

Page 31: ...rner orifice clean or replace Note do not use any metal cleaning device as this may damage the orifice 4 Pilot and burner come on but go out after some warm up A Inconsistent or insufficient flame on...

Page 32: ...2 Clear obstructions B3 Clear obstructions C If gas pressures are correct and the flames stay the same adjust the air shutter for a proper burn 9 Burner flashback Air gas mixture ignites inside the bu...

Page 33: ...tible for use with other gases unless a certified kit is used If the vent air intake system is disassembled for any reason reinstall per the instructions provided with the initial instructions This ve...

Page 34: ...or burn through TEK logs and embers against breakage cracking or burn through This warranty expires on the fifth 5th anniversary of the Purchase Date LIMITED THREE YEAR WARRANTY HearthStone warrants t...

Page 35: ...MENT EXTEND ONLY TO THE ORIGINAL PURCHASER OF THE STOVE WARRANTED HEREUNDER THEY DO NOT EXTEND TO ANY SUBSEQUENT OWNERS UNDER NO CIRCUMSTANCES SHALL HEARTHSTONE BE LIABLE TO THE ORIGINAL PURCHASER OR...

Page 36: ...Stove to HearthStone or a Dealer for repair HearthStone will pay fifty percent 50 and the Original Purchaser will pay fifty percent 50 of the shipping costs related to shipping the Stove to and from H...

Reviews: