WARNING: IF YOU DO NOT FOLLOW THESE
INSTRUCTIONS EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
CAUTION: LIGHTING THE TUDOR FOR THE FIRST
TIME AND ADJUSTMENTS TO THE UNIT SHOULD
BE PERFORMED BY QUALIFIED SERVICE
PERSONNEL.
This appliance is only for use with the type(s) of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a
certified kit is used.
Cet appareil doit être atilisé uniquement avec les
types de gas indiqués sur la plaque signalétique. Ne
pas l’utiliser avec d’autres gas sauf si un kited
conversion certifié est installé.
S
MOKE AND
F
UMES
W
ARNING
When lit for the first time, the Tudor will emit some
smoke and fumes. This is normal “off-gassing” of
the paints and oils used in the manufacturing and
assembly of the unit. Open windows to vent the
room if necessary. The off gassing and fumes will
subside after the first 10 to 20 minutes of operation.
O
DORS AND
I
MPURITIES
A heater of this type may produce odors during
heater operation due to impurities that may exist in
the immediate area. Sources of impurities can be
cleaning solvents, paint solvents, cigarettes,
candles, smoke, pet hair, dust, adhesives, new
carpet, and/or textiles. Such odors will dissipate.
However, opening a window or otherwise providing
additional ventilation to the area can alleviate the
condition. If any odor persists, contact your dealer or
an authorized service technician.
P
ILOT
L
IGHT
W
ARNING
The Tudor has a piezoelectric spark igniter (the red
push button located next to the gas control valve
behind the valve access door), which ignites the pilot
light by means of a spark at the pilot light assembly.
Do not attempt to light the unit with a match or by
any means other than the piezoelectric spark.
D
O
N
OT
L
IGHT
P
ILOT OR
TEK
B
URNER
B
Y
H
AND
The standing pilot light on this gas heater is lit by
using a piezoelectric spark generator as described
elsewhere in this manual. Never attempt to light the
pilot or main burner by hand with a match or lighter.
If, after repeated attempts, the pilot light fails to light,
discontinue operation; turn off the gas at the gas
control valve, and immediately contact qualified
service personnel for assistance.
P
REPARE
F
OR
L
IGHTING
Prepare for the lighting procedure by adjusting the
thermostat (if equipped) to its lowest setting or OFF
position. If the gas control knob is not in the OFF
position, turn the knob fully clockwise to OFF. Locate
the variable output control knob and turn it fully
clockwise to the highest setting.
Prior to lighting the unit for the first time, wait 5
minutes to allow any residual gas within the unit to
dissipate. Smell all around the appliance area for
gas. Be sure to smell next to the floor because some
gases are heavier than air and will settle on the
floor. If you do not smell gas after this five-minute
period, proceed with the lighting procedure. If you do
smell gas, DO NOT proceed with the lighting
procedure. Instead,
immediately refer to the What
To Do If You Smell Gas Warning, on the cover of
this manual.
WARNING: THE VALVE CONTROL HAS AN
INTERLOCK DEVICE. AFTER SHUTTING OFF ALL
GAS FLOW, THE PILOT BURNER CANNOT BE
RELIT UNTIL THE THERMOCOUPLE HAS
COOLED, ALLOWING THE ELECTROMAGNET TO
BE RELEASED (APPROX. 60 SECONDS). THE
GAS CONTROL KNOB IS DESIGNED TO
OPERATE BY HAND. DO NOT USE ANY TOOLS
DURING THIS OPERATION. DAMAGED KNOBS
MAY RESULT IN SERIOUS INJURY.