background image

Hearthstone Quality Home Heating Products, Inc.                               

    TUDOR 8120 Gas-Fired Direct-Vent                                   

P

ARTS 

L

ISTS

 

Part #   

Part Name 

 

 

  Part 

 Part 

Name

 

 

CAST  

2110-205 Tudor 

feet 

2110-210 Tudor 

base 

2110-220 

Tudor front, lower control door 

2110-250 

Tudor side, left 

2110-255 

Tudor side, right 

2110-260 

Tudor door, left 

2110-265 

Tudor door, right 

2110-268 Tudor 

façade 

2110-275 

Tudor base, heat exchanger 

2110-277 

Tudor heat exchanger 

2110-280 Tudor 

top 

 

 

  

  

STEEL 

5120-001 knob 

 

5120-005 

Door Hinge Left Assembly 

5120-006 

Door Hinge right Assembly 

5120-010  

Valve Bracket 

5120-017  

Shutter, Primary air plenum 

5120-019 

Primary air plenum 

5120-020 Pilot 

Shield 

5120-027  

hinge angle control door    

5120-028 

front casting hinge  

5120-030 

front sheet metal Stone ret door 

5120-032  

Control panel 

5120-038  

knob extension, front door 

5120-041  

lower baffler support, LEFT 

5120-042  

lower baffler support, RIGHT 

5120-050  

firebox 

5120-055  

Glass retention frame 

5120-057 

heat shield , rear 

5120-062  

side stone clip right 

5120-064  

side stone clip left 

5120-066 magnet 

support 

bracket 

5120-070  

air inlet chamber 

5120-076 Restrictor 
5120-078 Restrictor 

Indicator 

5120-080  

Glass retention clips 

5120-082  

Glass plate clip 

5120-085  

façade retention clip 

5120-092  

heat shield, top 

 

GAS COMPONENTS 

7200-453 

orifice NG #53 

7210-008 

fitting  3/8"NPTx3/8" comp 90deg  

7210-103 IGNITOR:MILLIVOLT 
7211-003 fitting 

3/8"COMP 

x 1/4"NPT straight 

7211-053 Gas 

manifold 

7211-131 

pilot orifice NG 

7211-300 VALVE 
7211-370 

3 way pilot SIT 

7211-407 SIT 

1" 

knob 

extention ON/OFF 

7211-404  

SIT 1” knob extension HI/LO 

7211-027 

GAS LINE 3/8" X 6" 

 

CONVERSION KIT 

7200-463 ORIFICE 

LP 

#63 

7211-136 ORIFICE: 

PILOT,LP,.35mm, 

7211-307 REGULATOR: 

VALVE,LP,SIT 

  

  

 

TEK BURNER (PYROTEK) 

 Refractory liner  interior panel set 
3120-140  

 interior top 

3120-141  

 interior left 

3120-142 

 interior right 

3120-143 

 interior rear 

3120-125 

 heatshield: top 

7211-536 Ember 

bed 

7211-537 rear 

log 

7211-538 front 

log 

  

  

 

ELECTRICAL 

7000-014 

Thermostat wire 40' 

7000-031 HARNESS: 

WIRE,ON/OFF 

7000-200 

3 way switch - ON/OFF/T-stat 

  

  

 

MISC 

3030-044 

Glass (17.7" x 10.8") 

3300-334 

Plate for 3 way switch - ON OFF Tstat 

4700-0795 Magnet, 

round 

3160-152 Gasket: 

Pilot 

3160-155 

Gasket; Exhaust starter collar 

3160-157 

Gasket; Inlet starter collar 

3160-080 

GASKET: TAPE,3/4" x 1/16" 

3160-121 

Heat exchanger base gasket 

3160-123 Gasket: 

Burner 

3160-122 

Heat exchanger gasket 

5701-0923TU COLLAR: 

INLET/EXIT,4"x6-5/8",TUDOR 

3120-126 

Blanket Insulation 1” x 6.5” x 29” 

  

  

CURIO-All cast  

2110-296 

panel, cast; side or front, upper 

2110-292 

panel, cast;front, lower 

2110-294 

panel, cast; side, lower 

3120-124 

ceramic heatshield: front door 

5120-053  

CAST RETENTION, LEFT DOOR 

5120-054  

CAST RETENTION, RIGHT DOOR 

4500-3436 

10-24 x3/8 Screw (8) 

  

  

HEIRLOOM-Stone  

Stone set 

(1141-233 Soapstone)(1153-233 Aut.Brown) 

1141-232 

stone door/side Pol. soapstone                     

1141-231 

stone front  Pol. soapstone                         

1141-230 

stone side sm   Pol. soapstone                   

3160-120 

Front door heat shield 

5120-051  

STONE RETENTION, FRONT DOOR 

4500-3436 

10-24 x3/8 Screw (8) 

  

  

KEEPSAKE-Grill+Cast  

2110-296 

panel, cast; side or front, upper 

2110-292 

panel, cast;front, lower 

2110-294 

panel, cast; side, lower 

2110-298 

grille, front door 

5120-052  

grille retention front door 

 

91-68200

 

Tile Insulation Kit –

This kit is required to 

lower surface temps and to retain the tiles you have 
purchased. 

 

 

W

ARNING

:

   

D

N

OT 

S

UBSTITUTE 

M

ATERIALS

.

 

F

OR 

REPLACEMENT PARTS

,

 OR FOR INFORMATION ABOUT 

PARTS OR SERVICE

,

 CONTACT YOUR AUTHORIZED 

H

EARTH

S

TONE RETAILER

.

   

F

OR THE NAME OF THE 

AUTHORIZED RETAILER NEAREST TO YOU

,

 VISIT OUR 

WEBSITE WWW

.

HEARTHSTONESTOVES

.

COM

,

 OR WRITE

 

Hearthstone Quality Home Heating Products, Inc. 
317 Stafford Ave. 
Morrisville, Vermont 05661-8695 
E-Mail: inquiry@hearthstonestoves.com 

 

 

 

29

Summary of Contents for Tudor 8120

Page 1: ...ervice agency or gas supplier must perform installation and service In the Commonwealth of Massachusetts all installation of gas lines and gas fitting must be done by a licensed gas fitter or licensed...

Page 2: ...Hearthstone Quality Home Heating Products Inc Tudor Model 8120 2...

Page 3: ...p your original receipt in a safe place as proof of purchase Serial Number Fuel type check one Natural Gas Liquid Propane Sold by Phone Date of Purchase Installed by Phone Date of Installation Gas Sup...

Page 4: ...S 16 REMOTE CONTROL 16 THERMOSTAT WIRING 16 WIRING SCHEMATIC 17 GAS SUPPLY CONNECTIONS 19 GAS CONNECTIONS 19 GAS SUPPLY 19 GAS PRESSURE ADJUSTMENT 19 REFRACTORY PANEL INSTALLATION 20 PANEL PLACEMENT 2...

Page 5: ...OR SLAMMING SHUT REPLACEMENT OF THE GLASS PANEL SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON Replace any shield door or safety screen component removed for servicing prior to operating th...

Page 6: ...3 M02 CAN CGA2 17 M91 Certified for Canada CSA P 4 1 Approved for Mobile Home Installation Figure 1 Tudor Dimensions FUEL TYPE NG LP INPUT RATING Btu hr 0 2000 ft 11 500 11 200 ORIFICE SIZE DMS 0 2000...

Page 7: ...he homeowner can select the optimum flame size for their setting and application During the summer non heating season switch the wall thermostat to OFF and turn off the pilot This will improve the ove...

Page 8: ...nts are supplied separately Failure to use the venting components specified by Hearthstone QHHP Inc will void your warranty and could risk a fire UNPACKING AND INSPECTION Unpack and Inspect for Damage...

Page 9: ...ved prior to any other connections have been made Once removed lift the unit off the legs and set in the desired location CLEARANCE TO COMBUSTIBLES Due to high surface temperatures locate the unit out...

Page 10: ...ality Home Heating Products Inc Tudor Model 8120 6 straight Minumum Venting Components Rear wall clearance 0 Termination cap Wall pass through Insulation blanket Mantle clearance Figure 3 Minimum vent...

Page 11: ...Hearthstone Quality Home Heating Products Inc Tudor Model 8120 Acceptable Direct Vent TERMINATION CAP LOCATIONS Figure 4 Termination clearances 11...

Page 12: ...lable Controlling the draft also changes the aesthetics of the flame The restriction plate consists of a rotating shutter behind the starter section of pipe and an adjustment plate with an index hole...

Page 13: ...Hearthstone Quality Home Heating Products Inc Tudor Model 8120 Figure 6 Venting configurations 13...

Page 14: ...tallations 90 0 Elbow 45 0 Elbow 6 Straight 9 Straight Simpson only 12 Straight 24 Straight 36 Straight 48 Straight 11 14 5 8 Adjustable Pipe Length Horizontal Vent Cap Vertical Vent Cap 14 Snorkel Vi...

Page 15: ...t using the straps from the horizontal vent termination to the interior 6 pipe with 2 sheet metal screws keeping the screws close to the wall thimble as possible Bend or cut the excess strapping so th...

Page 16: ...5m off the floor and away from any influences that may cause the temperature in the vicinity of the thermostat to be unrepresentative of the room temperature in general Such influences might include s...

Page 17: ...RATION AFTER SERVICING ATTENTION AU MOMENT DE L ENTRETIEN DES COMMANDES TIQUETEZ TOUS LES FILS AVANT LE D BRANCHEMENT DES ERREURS DE C BLAGE PEUVENT ENTRA UN FONCTIONNEMENT INADEQUATE ET DANGEREUX THE...

Page 18: ...Hearthstone Quality Home Heating Products Inc Tudor Model 8120 18 Figure 10 Gas control valve...

Page 19: ...gas supply to meet the maximum demand of the unit without undue loss of pressure We recommend a flexible line to avoid undue mechanical load on the valve and to ease thread alignment but refer to loc...

Page 20: ...and inspect for damage or missing parts Contact your dealer if necessary 5 The panels are very fragile do not force them into position 6 Insert the rear panel into the firebox right edge first rotate...

Page 21: ...the front grasp both sides of the front cast facade and lift upward and then outward Set the front aside taking care not to chip or scratch the enamel Next locate the two rotating clips above the glas...

Page 22: ...cast by sliding the upper portion onto the lip of the top and tilting the bottom in flush with the glass assembly It should fit snuggly in place Ensure the glass assembly is properly secured to the f...

Page 23: ...xt to the gas control valve behind the valve access door which ignites the pilot light by means of a spark at the pilot light assembly Do not attempt to light the unit with a match or by any means oth...

Page 24: ...old in Immediately light the pilot with the gas lighter push in and click the piezoelectric spark igniter button several times until lit Continue to hold the control knob in for about 20 seconds after...

Page 25: ...must perform supply line manifold gas line pressure adjustments and restrictor plate adjustments Do not attempt to complete any part of the installation or adjustment of this unit unless technically...

Page 26: ...burner flame should be performed The burner flames can be adjusted by means of the air shutter To determine if the burner flame needs adjustment it is necessary to view the flame pattern with the var...

Page 27: ...ccording to the lighting instructions described on page 22 Check to insure a proper flame is burning from each burner port The pilot flame should be large enough to engulf the thermopile and thermocou...

Page 28: ...will weaken the integrity of the glass Do not clean the glass when hot Allow the glass to cool and apply a mild window cleaning fluid Special gas appliance window cleaner is available from your local...

Page 29: ...3120 140 interior top 3120 141 interior left 3120 142 interior right 3120 143 interior rear 3120 125 heatshield top 7211 536 Ember bed 7211 537 rear log 7211 538 front log ELECTRICAL 7000 014 Thermost...

Page 30: ...insulation If properly connected and no spark replace igniter E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas pres...

Page 31: ...rner orifice clean or replace Note do not use any metal cleaning device as this may damage the orifice 4 Pilot and burner come on but go out after some warm up A Inconsistent or insufficient flame on...

Page 32: ...2 Clear obstructions B3 Clear obstructions C If gas pressures are correct and the flames stay the same adjust the air shutter for a proper burn 9 Burner flashback Air gas mixture ignites inside the bu...

Page 33: ...tible for use with other gases unless a certified kit is used If the vent air intake system is disassembled for any reason reinstall per the instructions provided with the initial instructions This ve...

Page 34: ...or burn through TEK logs and embers against breakage cracking or burn through This warranty expires on the fifth 5th anniversary of the Purchase Date LIMITED THREE YEAR WARRANTY HearthStone warrants t...

Page 35: ...MENT EXTEND ONLY TO THE ORIGINAL PURCHASER OF THE STOVE WARRANTED HEREUNDER THEY DO NOT EXTEND TO ANY SUBSEQUENT OWNERS UNDER NO CIRCUMSTANCES SHALL HEARTHSTONE BE LIABLE TO THE ORIGINAL PURCHASER OR...

Page 36: ...Stove to HearthStone or a Dealer for repair HearthStone will pay fifty percent 50 and the Original Purchaser will pay fifty percent 50 of the shipping costs related to shipping the Stove to and from H...

Reviews: