Hearthstone Quality Home Heating Products, Inc.
Tudor Model #8120
S
PECIFICATIONS
L
ISTED AS
:
Gas-Fired Direct-Vent Fireplace Heater
Model:
Tudor Direct-Vent Gas Fireplace Heater (8120)
Testing Agency:
OMNI-Test Laboratories, Inc.
Tested to:
ANSI Z21.88-B 2003, CSA 2.33-M02, CAN/CGA2.17-M91
Certified for Canada, CSA P.4.1
Approved for Mobile Home Installation
Figure 1: Tudor Dimensions
FUEL TYPE:
NG LP
INPUT RATING (Btu/hr) 0-2000 ft
11,500
11,200
ORIFICE SIZE (DMS) 0-2000 ft
53
63
MANIFOLD PRESSURE - LO SETTING (in. W.c./kpa)
1.6/0.42
6.4/1.59
MANIFOLD PRESSURE - HI SETTING (in. W.c./kpa)
3.5/1.15
10.0/2.48
INLET PRESSURE - LO (in.w.c./kpa)
5.0/1.24
11.0/2.88
MINIMUMINPUT RATING (btu/hr)
7000
8500
MAXIMUMOUTPUT (btu/hr) 0-2000 ft
7652
7494