The installation must conform with local codes or,
in the absences of local codes, the current National
Fuel Gas Code, ANSI Z223.1 (NFPA 54) or
CAN/CGA B149 Installation Code.
(Installer
l’appareil selon les codes ou règlements locaux,
ou, en l’absence de tels règlements, selon les
Codes d’installation CAN/CGA-B149.)
Warning: Do not use this appliance if any part
was submerged. Immediately call a qualified
service technician to inspect the heater and to
replace any part of the control system and gas
control that was under water. (Ne pas se servir
de cet appareil s’il a été plongé dans l’eau,
complètement ou en partie. Appeler un
technicien qualifié pour inspector l’appareil et
remplacer toute partie du système de contrôle et
toute commande qui ont été plongés dans l’lau.)
D
AILY
O
PERATION
The Tudor is easily operated by the homeowner
once installed and adjusted by qualified service
personnel. The unit can be controlled via the wall-
mounted thermostat during the heating season. Set
the thermostat to the desired room temperature and
the unit will cycle on and off as required. By
adjusting the variable output control located on the
gas control valve, the rate of heat output can be
varied to meet the heating requirements of the
season. Choosing a low flame setting will result in
longer burn cycles at a reduced output, while
choosing a high flame setting will result in a shorter,
hotter burn cycle. Through trial and error, the
homeowner can select the optimum flame size for
their setting and application. During the summer
non-heating season, switch the wall thermostat to
“OFF”, and turn off the pilot. This will improve the
overall efficiency of the unit as the heat from the pilot
is wasted. When putting the unit back into service,
follow the lighting instructions described on page 24.
When the unit is first lit, especially when cool, it is
normal to experience some condensation on the
inside of the window glass. This condensation will
burn off within the first few minutes of operation. If
continuous condensation on the window glass or
dripping water from any part of the unit or venting
system (chimney) is noted, immediately discontinue
operation of the unit and contact qualified service
personnel.
Clean the area around, under, and behind the unit
on a regular basis to prevent the accumulation of
dust and lint.
The Tudor requires minimal routine maintenance
and care. It should always be cool and off when
being cleaned, or serviced. Once a year, the unit,
and venting system should be inspected by qualified
service personnel to insure that they are clean, free
of obstruction, safe, and in good working order. If
service or maintenance is required, qualified service
personnel should perform it.
S
ERVICE
C
AUTION
If you believe your Tudor is not, in any way,
performing properly, immediately discontinue
operation until the unit is inspected and approved by
qualified service personnel. Prior to servicing the
unit, turn the valve control knob clockwise to “OFF”.
The unit should be cool prior to servicing and
cleaning.
Use of any components not supplied by Hearthstone
on the stove voids all warranties.