HearthStone Quality Home Heating Products Inc
Tudor Model #8120
13
V
ENTING
C
OMPONENTS
&
C
ONFIGURATION
The Tudor cannot be vented jointly with any
other solid fuel or gas appliance. It must be
vented directly to the outside of the building
using a proper termination as listed in the
manual. The only types of venting pipe
approved for use with your Tudor Direct-
Vent stove is Simpson Dura-Vent’s GS,
AmeriVent Direct,
Selkirk Direct Temp™
and
Secure Vent Direct-Vent Pipe. The venting
configuration is shown in
Figure 6
. After
determining the venting configuration for
your stove, select the vent system that will
accommodate your installation.
Caution: Be sure there is no wiring or
plumbing in the chosen location.
Caution: Venting terminals shall not be
recessed into a wall or siding.
Note:
If further direction is needed for
installation, please refer to the venting
instructions, which are provided with the
venting components.
Acceptable Direct-Vent
Termination Cap Locations
The vent/air intake termination clearances
above the high side of an angled roof are as
follows:
Roof Pitch
Feet Meters
Flat to 6/12
1
0.3
7/12 to 9/12
2
0.6
10/12 to 12/12 4
1.2
13/12 to 16/12
6
1.8
17/12 to 21/12 8
2.4
Listed are Simpson Dura-Vent, AmeriVent
Direct,
Selkirk Direct Temp™
and Secure
Vent components acceptable for installation,
along with the minimum venting kit
available. The venting system must be
comprised of the appropriate venting
components as specified.
A
PPROVED
V
ENTING
S
YSTEM
C
OMPONENTS
(T
HE FOLLOWING ARE COMPONENTS THAT
ARE AVAILABLE
,
BUT
NECESSARY FOR ALL
INSTALLATIONS
)
90
0
Elbow
45
0
Elbow
6" Straight
9" Straight (Simpson only)
12" Straight
24" Straight
36" Straight
48" Straight
11"-14
5/8"
Adjustable Pipe Length
Horizontal Vent Cap
Vertical Vent Cap
14” Snorkel
Vinyl Siding Standoff 4 x 6
5/8"
Round Ceiling Support Wall
Thimble Covers
Wall thimble
Wall Pass Through Insulation Blanket
(Required wherever a wall pass through is
installed)
C
HIMNEY
L
INER
S
YSTEM
1. Direct-Vent Chimney Liner Termination
Kit
2. Chimney Liner Flex
3. Co-Linear Flex Connector
4.
Co-Axial to Co-Linear Appliance
Connect
(Masonry approved, not to
exceed 16’)
M
INIMUM
V
ENT
K
IT
6” Straight
Wall Thimble Cover (optional)
Wall Thimble
Horizontal Vent Cap
Wall thimble Insulation Blanket (Supplied by
HearthStone
)