HearthStone Quality Home Heating Products, Inc.
TUDOR 8120 Gas-Fired Direct -Vent
23
L
IGHTING
I
NSTRUCTIONS
NOTE:
The gas control knobs and the piezo
igniter are located behind the control valve
access door, under the front of the unit.
1. STOP! Read the What To Do If You
Smell Gas! Warning (on the cover of
this manual).
2. Set the on/off/T’stat switch or thermostat
to the “OFF” position.
3. Push in and turn gas control knob
clockwise to “OFF”.
(If not previously
lit, the knob should be in this position.)
4. Wait (5) five minutes to clear out any
gas. If you then smell gas, STOP!
Smell
all around the appliance area for gas.
Be sure to smell next to the floor because
some gases are heavier than air and will
settle on the floor
. If you smell gas
immediately follow the What To Do If
You Smell Gas!
warning on the cover of
this Manual.
If you do not smell gas,
proceed to the next step.
5. Turn gas control knob counter-clockwise
to “PILOT”.
6. Push in control knob all the way and
hold in. Immediately light the pilot with
the gas lighter (push in and “click” the
piezoelectric spark igniter button several
times until lit). Continue to hold the
control knob in for about 20 seconds
after the pilot is lit. Release the knob and
it will pop back out. Pilot should remain
lit. If the pilot goes out, repeat the
operation.
•
If knob does not pop out when released,
stop, shut off the gas supply to the heater
and immediately call a qualified service
technician or gas supplier.
•
If the pilot will not stay lit after several
tries, turn the gas control knob “OFF”
and call a qualified service technician or
gas supplier.
7. After the pilot lights, turn gas control
knob counter-clockwise to “ON”.
8.
If the ON/OFF/T’stat switch is set to
“ON”, the stove should now be lit. If the
thermostat (or remote) has been
installed, set the ON/OFF/ T’stat switch
to “T’stat” and turn the thermostat (or
remote) to “ON”. Then set the desired
temperature.
9. Shut the gas control valve access door.
10. Plug in the fan accessory, if so equipped.
11. If T’stat was selected, set thermostat to
“ON” and set desired temperature
setting. Normally, if T’stat position was
selected, the main burner is cycled on
and off by the thermostat or the “on/off”
switch located on the bottom of the
thermostat body.
NOTE
:
When pressing/clicking the
piezoelectric spark ignition button to light
the pilot, watch through the glass (front) of
the unit. Click the igniter button until a
flame is visible at the pilot. Once the pilot is
lit, continue to press on the gas control knob
for another 20 seconds, then release.
Ascertain that the pilot is still lit by looking
through the front door. If lit, then turn the
gas control knob fully counter-clockwise to
the “ON” position. If the pilot fails to light,
or if it went out due to a premature release
of the gas control knob while depressed in
the “PILOT” position, wait 60 seconds for
the Interlock to release. Then repeat the
lighting process as described in this section
of the manual.
Once the pilot has been lit, the gas control
knob has been turned to the “ON” position,
and the ON/OFF/T’stat switch has been
turned to “ON”, the main burner should light
immediately. If you would like to use the
thermostat and it has been installed, switch
the ON/OFF/T’stat switch to thermostat.
Turn the thermostat to "ON" and set it to a
higher position so that it "calls" for heat in
order to light the main burner (i.e. turns the