HearthStone Quality Home Heating Products, Inc.
TUDOR 8120 Gas-Fired Direct -Vent
27
combustion and ventilation air is not
obstructed.
R
EPLACE THE
G
LASS
G
ASKET AS
N
EEDED
Your Tudor uses a 3/4” tape-style fiberglass
gasket to make a tight seal between the
doorframe and the firebox. In time, the
gasket can become brittle and compressed
and should be replaced. New gasket material
is available from your Authorized
HearthStone Dealer. Protect your hands with
work gloves, and wash up later.
1. Allow the Tudor to cool completely.
2. Remove the front cast and glass frame as
described in the
Log Placement
section.
3. Using a 1/8” drill bit drill out the rivet in
the top center of the glass frame. This
will allow the glass to free up from the
steel.
4. Remove the existing gasket by grasping
one end and pulling firmly. Clean the
remaining adhesive on the glass off with
warm soapy water. Let dry.
5. Determine the correct length of the
appropriate-sized gasket by wrapping it
around in the glass. Allow an extra 1 to
2” (25-50mm), and mark the spot to be
cut.
6. Cut the gasket at the marked spot with a
utility knife.
7. Starting at one end, pull the paper off the
back of the gasket and center the gasket
over the glass. Continue around the glass
until you meet up where you started. Do
not overlap the gasket ends or leave ends
with ragged edges.
8. Firmly and evenly, press the gasket to
seat it in its channel.
9. Sandwich the glass within the glass
frame and glass gasket clip.
10. Using a 1/8”x1/8” rivet, reattach the
glass gasket clip to the glass frame
G
LASS
C
LEANING
As fuel gas may contain some impurities; it
will be necessary to clean the inside of the
glass occasionally. Do not use abrasive
cleaners. Scratching the glass will weaken
the integrity of the glass.
Do not clean the
glass when hot!
Allow the glass to cool and
apply a mild window cleaning fluid. Special
gas appliance window cleaner is available
from your local HearthStone dealer.
•
WARNING:
Do not operate this
appliance with the glass panel removed,
cracked, or broken. Do not subject the
door to abuse, such as striking or
slamming shut. Replacement of the glass
panel should be done by a licensed or
qualified service person.
V
ENTING
The venting system should receive a
periodic examination by a qualified agency.
If the vent-air system is disassembled for
any reason, re-install per the instructions
provided in the venting section of this
manual, being sure to reassemble and reseal
the venting properly.