HearthStone Quality Home Heating Products Inc
Tudor Model #8120
8
found or suspected, contact your dealer for
instructions.
With the accessory box removed and set
aside, take care not to mar or chip the
enameled legs, if applicable. Have someone
help lift the stove out of the shipping box
and set it into place.
The TEK Burner and TEK Firelogs supplied
with the Tudor are contained in the
accessory box. Always use great care when
handling the decorative fire logs, as they are
fragile and subject to damage and breakage
if handled roughly. If a broken log is
encountered, contact your dealer for
replacement logs. Otherwise, set the logs
aside until called for during the installation.
INSTALLING THE TUDOR
A complete Tudor REQUIRES the
purchase of one of the following panel
kits;
91-8220010 Curio Matte (cast iron)
91-8220020 Curio Brown
91-8220059 Curio Blue/black
91-8220310 Keepsake Matte (grill + cast)
91-8220320 Keepsake Brown
91-8220359 Keepsake Blue/black
91-8220641 Heirloom Polished (stone)
91-8220653 Heirloom Brown
91-68200
Tile Insulation kit
(Must be
used with self purchased
tiles)
Do not paint, plaster or
finish the tiles in any way.
This may risk off gassing or a
fire.
H
EARTH
R
EQUIREMENT
/F
LOOR
P
ROTECTION
The Tudor may be placed on any surface or
wood floor, carpeting, or vinyl tile, with or
without legs. Installations must meet local
codes.
Removing the Tudor’s legs
The Tudor has the unique possibility of
having its legs removed, allowing for the
unit to rest on its base. To do this, simply
use two 7/16” wrenches or ratchets and
loosen and remove the two centermost ¼-20
bolts and nuts holding the legs on. These can
be reached the easiest from behind the unit
and should be removed prior to any other
connections have been made. Once
removed, lift the unit off the legs and set in
the desired location.
C
LEARANCE TO
C
OMBUSTIBLES
Due to high surface temperatures, the unit
should be located out of traffic and away
from furniture and draperies. Clothing and
other flammable material should not be
placed on or near the heater. When
positioning the unit always maintain
adequate clearances around air openings into
the combustion chamber and allow for
adequate ventilation. Minimum clearances
to combustibles must be maintained as
shown in the illustrations of the
Clearances
To Combustibles
section.
Be sure to consider the need for access to
the gas control valve access door on the
front of the unit as well as full access for
periodic cleaning and servicing.
Caution:
These clearances represent
minimum
distances in all cases, which,
through testing in an independent
laboratory to ANSI and CSA standards,
will prevent fire or spontaneous
combustion. We do not control the
combustible materials exposed to heat by
this product; therefore, an assessment
must be made by the installer to prevent
consequential damage of walls and
flooring.