Section 5-3
22
MLSM2003-01-03
Procedure 6
- Thermostat Oven Probe
Step 1: Disconnect power supply
to range.
Step 2: Pull range away from wall.
Step 3: Remove range’s back
panel (see procedure 32)
Step 4: Remove oven door (see
procedure 33)
Step 5: Remove convection fan
baffle. remove all racks (push as
far back as they will go, lift back
end of rack and pull out).
Step 6: Remove right and left rack
supports by removing locking nuts
(please note that there is a left and
right rack support, with the “v”
always facing downward).
Step 7: Remove baffle’s two
bottom screws first (you may use a
prop for the baffle such as 2” wide
masking tape roll)
Step 8: Remove top two screws
and gently pull baffle plate out
clearing oven probe’s opening.
Step 9: Place tape overtop probe’s
screw heads inside oven.
Step 10: Disconnect molex plug
from oven thermostat probe (grey
sheath cable & grounding screw)
Step 11: Remove nut holding
thermostat probe to shell and
replace with new probe.
Test oven Probe should read
around 1109 K ohms