Section 5-3
35
MLSM2003-01-03
Procedure 18
- Timer Relay Board
Step 1: Disconnect power supply
to range and pull unit away from
wall.
Step 2: Remove relay access
panel (see Procedure 32). Panel is
held in by a series of self tapping
screws.
Step 3: Carefully pull away from
range and drop relay cover to
access relay board.
Step 4: Remove one wire at a time
from faulty relay board unto new
board.
Step 5: Remove four nuts holding
relay board to access panel -
ensure that non conductive spacers
are also transferred to new board.