Section 5-3
38
MLSM2003-01-03
Procedure 21
-
25 amp Relay
(36” Models only)
Step 1: Disconnect power supply
to range and pull unit away from
wall.
Step 2: Remove relay access
panel (see Procedure 18). Panel is
held in by a series of self tapping
screws.
Step 3: Carefully pull out and drop
relay cover to access 25 amp
Relay.
Step 4: If range’s oven is not
operational, pull wires from relay
and test continuity across each
side. If relay faulty, replace.
Sometimes relays malfunction only
under load - carefully plug range
ensure no wires are making contact
with any metal parts and test for
voltage across the relay.
Step 5: If relay is faulty, replace
and transfer wires to new relay in
the same sequence.
Step 6: Remove screws securing
relay to access panel and attach
new 25 amp relay.