Section 5-3
45
MLSM2003-01-03
Procedure 27
- Burner Caps
Step 1: Nuisance sparking and
erratic flames can be caused by
improper positioning of burner caps
onto the burner base.
Step 2: Caps must “lock” in place
to ensure a flat surface is provided
and flames are evenly distributed
out of cap ports.
Burner ring not locked results in
uneven flames
Ports
Important: tab must
be locked in position
on the burner base
Step 3: Other causes for erratic
sparking are moisture inside caps
(specially after washing) or food
particles blocking the ports.
correct
incorrect