4
Heat & Glo • TIARA II-B • 7011-148 Rev. G • 10/12
1
Listing and Code Approvals
The product is listed to ANSI standards for “Vented Gas
Appliance Heaters” and applicable sections of “Gas Burning
Heating Appliances for Manufactured Homes and Recre-
ational Vehicles” and "Gas Fired Appliances for use at High
Altitudes".
A. Appliance Certi
fi
cation
B. Glass Speci
fi
cations
NOTE:
This installation must conform with local codes. In the
absence of local codes you must comply with the
National
Fuel Gas Code, ANSI Z223.1-latest edition
in the U.S.A.
and the
CAN/CGA B149 Installation Codes
in Canada.
D. High Altitude Installations
C. Speci
fi
cations
This appliance is equipped with 5mm ceramic glass behind
the curved glass. Replace glass only with 5mm ceramic
glass. Please contact your dealer for replacement glass.
Manufactured Home or Mobile Home installation may occur
only after the home is site located and must conform with
the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280, or, when such a standard is
not applicable, the Standard for Manufactured Home
Installations, ANSI/NCSBCS A225.1, or Standard for Gas
Equipped Recreational Vehicles and Mobile Housing, CSA
Z240.4.
When installed, the appliance must be electrically grounded
in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1.
*Maximum Vent Blower On
**Canada Only
MODEL
Tiara II B
LABORATORY
OMNI-Test Laboratories, Inc.
061-S-44b-5
TYPE
Vented Gas Fireplace Heater
STANDARD
ANSI Z21.88-2002
ּ
CSA 2.33-2002
UL307b
ּ
CAN/CBA 2.17-M91
Model
(US or Canada)
Maximum
Input
BTU
Minimum
Input
BTU
Orifi ce
Size
*Steady
State
Effi ciency
%
**P.4
%
Tiara II B
(NG)
38,500
27,000
.120
81.36
60.97
Tiara II B
(LP)
39,000
30,500
.073
83.62
64.14
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a Vertical
Tube Furnace at 750°C, shall be considered non-combustible
materials.
Materials made of or surfaced with wood, compressed
paper, plant fibers, plastics, or other materials that can ignite
and burn, whether flame proofed or not, or whether plastered
or unplastered shall be considered combustible materials.
E. Non-Combustible Materials
F. Combustible Materials
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
Intertek listed gas appliances are tested and approved
without requiring changes for elevations from 0 to 2000 feet
(0 to 609m) in the U.S.A. and 0 to 4500 feet (0 to 1372m)
in Canada.
When installing this appliance at an elevation above 2000
feet (609m), it may be necessary to decrease the input
rating by changing the existing burner orifi ce to a smaller
size. Input rate should be reduced by 4% for each 1000 feet
(305m) above a 2000 foot (609m) elevation in the U.S.A. If
the heating value of the gas has been reduced, these rules
do not apply. To identify the proper orifi ce size, check with
the local gas utility.
If installing this appliance at an elevation above 4500 feet
(1372m) in Canada, check with local authorities.