Heat & Glo • MEZZO36-C/ST-C, MEZZO48-C/ST-C, MEZZO60-C/ST-C, MEZZO72-C/ST-C Installation Manual • 2600-980 Rev. D • 9/19
34
Figure 4.19
Top Vent - Vertical Termination
Venting with 3 elbows
Note
: Use DVP Series
components only.
MEZZO36-C, MEZZO36ST-C
MEZZO48-C, MEZZO48ST-C
MEZZO60-C, MEZZO60ST-C
V
1
+
V
2
Minimum
H
1
+ H
2
Maximum
1-1/2 ft.
457 mm
4 ft.
1.2 m
3 ft.
914 mm
9 ft.
2.7 m
4 ft.
1.2 m
12 ft.
3.7 m
5 ft.
1.5 m
15 ft.
4.6 m
V
1
+ V
2
+ H
1
+ H
2
= 63 ft. (19.2 m) Maximum
H
1
+ H
2
= 23 ft. (7.1 m) Maximum
WARNING! Risk of Fire!
DO NOT
attach elbow directly to the appliance.
•
The MEZZO36-C/MEZZO36ST-C, MEZZO48-C/MEZZO48ST-C and MEZZO60/MEZZO60ST-C require a minimum of 18
inches of vertical venting before attaching any elbow to the appliance.
• The MEZZO72-C/MEZZO72ST-C requires a minimum of 30 inches of vertical venting before attaching any elbow to the
appliance.
MEZZO72-C, MEZZO72ST-C
V
1
+
V
2
Minimum
H
1 +
H
2
Maximum
2-1/2 ft.
762 mm
4 ft.
1.2 m
4 ft.
1.2 m
9 ft.
2.7 m
5 ft.
1.5 m
12 ft.
3.7 m
6 ft.
1.8 m
15 ft.
4.6 m
V
1
+ V
2
+ H
1
+ H
2
= 63 ft. (19.2 m) Maximum
H
1
+ H
2
= 23 ft. (7.1 m) Maximum
INSTALLED
HORIZONTALLY
H
1
H
2
V
2
v
1
V
1