59
Heat & Glo • MEZZO36-C/ST-C, MEZZO48-C/ST-C, MEZZO60-C/ST-C, MEZZO72-C/ST-C Installation Manual • 2600-980 Rev. D • 9/19
Facing Material
• Facing and/or finishing materials must not interfere with
air flow through decorative barrier fronts.
• Facing and/or finishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
Figure 10.2 Finishing and Facing Materials - Single-Sided Models
Finishing - Hearth
See Inside Fit or Overlap Method sections to determine
the necessary requirements for installation of a non-
combustible hearth for this model. Only hearths made of
non-combustible materials are allowed.
BOTTOM
FINISHING
TEMPLATE
FINISHING
GUARDS
NON-COMBUSTIBLE
FINISHING MATERIAL
OVERLAP FIT = 0-1 IN. THICK
INSIDE FIT = 1-4 IN. THICK
1/2 IN. THICK WALL
SHEATHING
Decorative facing material thickness is measured from
the face of the installed non-combustible board. See
Figure 10.2 and Figure 10.3.
The fronts for this appliance are compatible with non-
combustible materials. See Figure 10.2 and Figure 10.3.
Refer to Section 1.E and 1.F of this manual for definitions
and qualifications of non-combustible and combustible
materials.
Specific requirements for each method of installation are
described in this section.
Installation of finishing materials can be accomplished
by either the “overlap” or “inside-fit” method, depending
on what type of decorative barrier front is to be installed.
See Figure 10.2 and 10.3. Overlap fit decorative barrier
fronts include the Quattro and Loft Forge. The Clean
Face Trim Front (CFT) can be either an inside fit or an
overlap fit. See Table 1.
Decorative Barrier Front
Finishing Method
Material Thickness
Trim Ring
Clean Face Trim (CFT)
Inside Fit
1-4 inches
Included & Not Used (Option #1)
Included & Used (Option #2)
Overlap Fit
0-1 inch
Included & Used
Quattro/Loft Forge
Overlap Fit
0-1 inch
Not included
Table 1
NOTICE:
The location of the Passive Heat discharge
opening could allow for venting and other construction
materials to be visible. It is acceptable to paint the vent pipe
and other construction materials using a high temperature
paint with a minimum of 300 °F continuous exposure rating.
Hearth & Home Technologies recommends using black
touch up paint (part number TUP-GBK-12) available from
your Hearth & Home Technologies dealer.