19
Heat & Glo • MEZZO36-C/ST-C, MEZZO48-C/ST-C, MEZZO60-C/ST-C, MEZZO72-C/ST-C Owner’s Manual • 2600-981 Rev. C • 10/19
4. Reinstall bottom glass shield.
5. Reinstall decorative barrier front.
Surrounds, Decorative Barrier Fronts
Frequency:
Annually
By:
Homeowner
Tools needed
: Protective gloves, stable work surface
• Assess condition of screen and replace as necessary.
• Inspect for scratches, dents or other damage and repair
as necessary.
•
Check that air intake and discharge areas are not
blocked.
•
Vacuum and dust surfaces.
Remote Control
Frequency:
Seasonally
By:
Homeowner
Tools needed:
Replacement batteries and remote con-
trol instructions.
• Locate remote control transmitter and receiver.
• Verify operation of remote. Refer to remote control
operation instructions for proper calibration and setup
procedure.
• Place batteries as needed in remote transmitters and
battery-powered receivers.
• Place remote control out of reach of children.
If not using your fireplace for an extended period of time
(summer months, vacations/trips, etc), to prevent unin-
tended operation:
• Remove batteries from remote controls.
• Unplug 6 volt adapter plug on IPI models.
Venting and Termination Cap
Frequency:
Seasonally
By:
Homeowner
Tools needed:
Protective gloves and safety glasses.
• Inspect exposed venting and termination cap for block
-
age or obstruction such as plants, bird nests, leaves,
snow, debris, etc.
• Verify termination cap clearance to subsequent construc-
tion (building additions, decks, fences, or sheds).
• Inspect for corrosion or separation.
• Verify caulking and sealing of vent components and
termination cap remains intact.
• Inspect draft shield to verify it is not damaged or missing.
Figure 4.1 Fixed Glass Assembly
BOTTOM RETAINING LIP
GLASS CLIPS