Figure 8.4 Assembling Chimney Sections
Attach
Flue First
CAK4A
Secure with Screws
Provided
Push Together
Secure to Top
NOTICE: Chimney Air Kit, Part CAK4A is REqUIRED when
using the SL-300 Pipe Series. Detailed instructions are
supplied with the kit.
1. Install the chimney pipe first.
2. Hand bend the tabs in position before placing on the
fireplace.
3. Place the box on top of the fireplace around the chimney
pipe, push both pieces together and secure with screws
provided.
4. Use the pre-punched holes in the tabs as guides and
drill holes through the fireplace top.
5. Secure the CAK4A in place.
6. Seal around the kit at the flue and at the top of the can
with caulk.
NOTES:
1. The outside termination cap must be a minimum of 6 ft
(1829 mm) above the ground and kept free of debris.
2. If the CAK4A is installed in a chase, the CAK4A side
termination cap must be at least 3 ft (914 mm) below
the chimney top.
3. Seal around the cap and flex with caulk to stop air from
getting in to the chase (See Figures 9.4-9.8 on page
52).
Figure 8.5 Installing the CAK4A
NOTICE: Chimney sections cannot be disassembled once
locked together. Plan ahead!
• Lock chimney sections and/or offsets/returns together
by pushing downward until the top section meets the
stop bead on the lower section.
• Pull on the top section to make sure it is fully engaged
and will not separate.
• You may use #6 or #8 sheet metal screws no longer
than 1/2 in. (13 mm) to fasten chimney sections
together. Do NOT penetrate inner flue.
WARNING! Risk of Fire! You MUST use screws (provid-
ed) to fasten offset/returns to chimney sections to keep
the chimney parts from twisting. Failure to do so could
cause fire.
• Fasten offset/returns to chimney sections. Insert the
screws (provided) through the predrilled holes. Do NOT
penetrate inner flue.
• Secure chimney returns with hanger straps provided;
fasten to studs or joists.
• Vertical straight runs of chimney must be supported
every 35 ft (10.7 m).
WARNING! Fire Risk!
The flex hose must never be compressed or deformed!
Use only those components described in this manual.
Substitute or damaged chimney components could impair
safe operation and cause overheating and fire.
Attach either a straight chimney section or an offset to the
top of the fireplace (depending on your installation require-
ment). Chimney sections are locked together by pushing
downward until the top section meets the stop bead on the
lower section.
The inner flue is placed to the inside of the flue section be-
low it. The outer casing is placed outside the outer casing
of the chimney section below it. See Figure 8.4.
WARNING! Risk of Fire! DO NOT install substitute or dam-
aged chimney components.
D. Assemble the Chimney Sections
E. Installing CAK4A and Flex Pipe