55
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. L • 4/15
Cold Climate Button
• Button Press: Turns on Climate Control
• Button Press: Turns off Climate Control
This allows the pilot
fl
ame to stay lit when activated. A
bene
fi
t of this is reduced condensation on the glass at
start-up in colder climate conditions.
Operation Under Battery Power
A switch on the control box allows for battery power under
no-power conditions (see Figure 12.5). By controlling the
power supply with this switch, the batteries are supplying
power only when needed, thus extending battery life. The
switch also provides a convenient means for switching to
battery power should there be a loss of 110 VAC power
to the control box.
• In the event of a power failure, switch the battery
operation switch to the “Battery ON” position.
• The
fi
replace can now be turned on and off with the
ON/OFF rocker switch located near the gas valve.
• The wall switch functions will not operate under battery
power.
• Under battery control the only available function is
fl
ame
“ON” and “OFF” in the high position.
• To maximize battery life, and to restore full function
capability of the wall switch,
fl
ip switch to “OFF” position
after 120 VAC power is restored.
Set Temperature Button
• Button Press: Displays Set Point
• Use UP and Down Arrows to adjust set point
• Press Set Button to store new set point
Temperature Set Point can be adjusted between the
ranges of 45-90° Fahrenheit or 7-32° Centigrade.
Up and Down Arrows
• Push to adjust set point temperature under automatic
control.
Auxiliary Button
• Button Press: Turns on ember lights
• Button Press: Turns off ember lights
Can be operated independently of all functions.
Child Proof Mode
To Enter Child Proof Mode:
• Press the Up Arrow Button twice and Down Arrow Button
once. The unit will send out three beeps and an indicator
in the LCD panel will show that the child proof is on.
To Leave Child Proof Mode:
• Press the Up Arrow Button twice and Down Arrow
Button once. The unit will send out three beeps and the
indicator in the LCD panel showing that child proof is on
will disappear.
CONTROL
BOX
"OFF"
POSITION
"BATTERY
ON" POSITION
BATTERY
OPERATION
SWITCH
Figure 12.5 Control Box
Note:
The controller will turn off the
fi
replace at 2° F over
set point and turn it back on at 2° F below set point.
Note:
When in Child Proof Mode, only the arrow buttons
will have functionality. Unit can enter Child Proof when the
fi
replace is on or off.