15
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Owner’s Manual • 2310-971 Rev. G • 9/15
HEAT-ZONE-PRIMO
The HEAT-ZONE-PRIMO is operated using a tempera-
ture switch. When the appliance is turned on, the HEAT-
ZONE-PRIMO will automatically turn on when the appli-
ance stabilizes at its operating temperature. This process
will take approximately 10-20 minutes.
After a quali
fi
ed service technician has installed the ap-
pliance, including the Heat-Zones
®
, follow the instruction
supplied with the appliance manual for operation. Contact
your dealer if you have questions.
WARNING! Risk of Fire!
Either the HEAT-ZONE-PRIMO
or the HEAT-OUT-PRIMO must remain ON during opera-
tion of the appliance. Overheating will occur. Appliance
will shut down.
Wall Switch
HEAT-ZONE-PRIMO &
HEAT-OUT-PRIMO Toggle
LED COLOR
SWITCHES
Figure 3.7 PowerFlow
TM
Heat Management and LED Switch
HEAT-OUT-PRIMO
The HEAT-OUT-PRIMO is operated using a temperature
switch. When the appliance is turned on, the HEAT-OUT-
PRIMO will not turn on until the temperature switch has
reached a predetermined temperature. This process will
take approximately 10-20 minutes.
After a quali
fi
ed service technician has installed the ap-
pliance, including the PowerFlow™ Heat Management
system, follow the instructions supplied with the appliance
manual for operation. Contact your dealer if you have
questions.
For additional information, see the instructions included
with the HEAT-ZONE-PRIMO or HEAT-OUT-PRIMO
product.
PowerFlow™ Heat Management System
The PRIMO requires a PowerFlow™ Heat Management
System. It may be either a HEAT-ZONE-PRIMO, which
diverts heat into an adjacent room, and/or HEAT-OUT-
PRIMO which will divert heat outside the home/building.
Power Vent System
PVI-SLP or PVLP-SLP
WARNING! Risk of Fire!
PRIMO models must be power
vented using PVI-SLP or PVLP-SLP. Failure to vent prop-
erly could cause overheating and
fi
re.
A quali
fi
ed service technician will install desired power vent
system at the time of appliance installation.
The PRIMO comes standard with a 2 minute pre-purge
function designed to remove cold air and excess gas from
the gas lines.
The PRIMO comes standard with a 20 minute post-purge
function designed to eliminate condensation in the venting
system components.
For additional information, see the instructions included
with the power vent product.