57
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
Figure 11.4 Cap Extension Installation
NO
EXTENSION
CAP
EXTENSION
INSTALLED
TO ELIMINATE
GAP
2 X 6 WALL
GAP
SLP-TRAP1 CAP
CAP EXTENSION
CAP EXTENSION INSTALLED
CAULK
PERIMETER
CAULK
PERIMETER
(EDGE)
4. Insulate wall per local code requirements. Use Ther-
max where an R19 insulation value is required.
See Figure 11.3 (C) and Figure 11.6.
5. Install In-Wall Tub as shown in Figure 11.3 (D). The
tub should set on the framing. Verify hood clips are in
the correct orientation. See Figure 11.5. Ensure tub is
level. Use eight screws (supplied with In-Wall Kit) to
attach the tub to the framing.
CAUTION!
In-Wall Tub and Appliance Outer Wrap
MUST be installed level for proper burner operation.
6. Install the required non-combustible board (supplied)
as shown in Figure 11.3 (E) using six screws.
WARNING! Risk of Fire! DO NOT
apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this instruction. Overlapping materials could ignite and
will interfere with doors.
7. Cut through insulation and wall as shown in Figure
11.3(E). Allow space for clearance for the firestop
framing disussed in step 11.
8. Remove the glass assembly from the firebox by re
-
leasing the two top glass latches and then the two
bottom glass latches. See Figure 12.1.
9. Remove firebox from outer wrap. See Figure 6.8.
10. Install the outer wrap as shown in Figure 3 (F & G)
using the four supplied bolts in the threaded holes.
Additional screws may be installed to ensure the tub
and the outer wrap are secured flat to one another.
11. Frame around the edges of the firestop cut out to en
-
sure insulation does not come into contact with the
vent pipe. See Figure 6.10 and 6.12.
12. Install firestop using the four supplied screws. See
Figure 6.10 and 6.11. See Section 6.A for reference
to sealing firestop.
13. Install finishing strips if applicable. See Figure 11.5.
14. Reattach firebox to outer wrap. Use Figure 6.8 and
6.13 for reference.
15. Replace the glass assembly on the appliance. Latch
the two bottom glass assembly latches and then the
two top glass latches. See Figure 12.1.
16. Attach the appliance vent system. See Section 6.A
for reference to sealing firestop.
NOTICE!
Install a cap extension if gap exists between
the wall and the back of the termination cap. See Figure
11.4. An SLP-TRAP1 will generally be used with In-Wall
installations.
17. Install vent and trap cap extension if a gap exists be-
tween the exterior wall and the cap. To prevent drafts,
the cap extension should be sealed with caulk that
has a minimum of 300ºF continuous exposure rating
to seal gaps of the extension. See Figure 11.4.