63
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-IPI • 2120-901 Rev. U • 11/13
A. Remove Fixed Glass Assembly
See Section 14.H.
B. Remove the Shipping Materials
Remove shipping materials from inside or underneath the
fi
rebox.
C. Clean the Appliance
Clean/vacuum any sawdust that may have accumulated
inside the
fi
rebox or underneath in the control cavity.
D. Accessories
Install approved accessories per instructions included
with accessories. Contact your dealer for a list of ap-
proved accessories.
WARNING! Risk of Fire and Electric Shock!
Use ONLY
Hearth & Home Technologies-approved optional acces-
sories with this appliance. Using non-listed accessories
could result in a safety hazard and will void the warranty.
14
14
Appliance Setup
Figure 14.1 Blower wiring
RHEOSTAT
SWITCH
TEMPERATURE
SENSOR
BLUE
VARIABLE
SPEED SWITCH
TEMPERATURE
SENSOR SWITCH
JUNCTION BOX
Figure 14.2 Detail of Fan Wiring with Rheostat
Figure 14.3 Placement of Embers
Figure 14.4
E. Lava Rock, Mineral Wool/Ember Placement
WARNING! Risk of Explosion!
Follow ember placement
instructions in manual. DO NOT place embers directly over
burner ports. Replace ember material annually. Improperly
placed embers interfere with proper burner operation.
Placing the Lava Rock (SL-350TRS-IPI only)
See Section 14.H for Lava Rock placement instructions.
Placing the Ember Material
Ember material is shipped with this gas appliance. To place
the ember material:
• Embers CANNOT be placed directly over ports. See
Figure 14.4 for the only exception to this guideline. Care
should be taken not to cover the lighting trail of ports
(from back to front).
• When placing Glowing Embers
®
onto the burner care should
be taken so that the ports are not covered. Place the dime-
size ember pieces near the port holes in the burner top (see
Figures 14.3 or 14.5). Failure to follow this procedure will
likely cause lighting and sooting problems.
• Some of the small port holes should be covered with
ember material. See Figure 14.4 for detail.
• Place Mytic Embers on areas of base refractory away from
port holes. Use this material to give the appliance a realistic
ash bed (SL-550TRS-IPI-E and SL-750TRS-IPI-E only).
• Save the remaining ember materials for use during appli-
ance servicing. The embers provided should be enough
for 3 to 5 applications.
EMBER MATERIAL
PORT HOLES IN SHADED
AREA SHOULD BE COVERED
WITH EMBER MATERIAL. NO
OTHER PORT HOLES MAY
COME INTO CONTACT WITH
EMBER MATERIAL.
SL-350TRS-IPI ONLY
SL-350TRS-IPI ONLY