64
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-IPI • 2120-901 Rev. U • 11/13
F. Install Refractory
SL-550TRS-IPI-E, SL-550TRS-E, SL-750TRS-IPI-E and
SL-750TRS-E only.
Figure 14.7
Figure 14.6
Figure 14.8
Step 2.
Place the right refractory against the
fi
rebox right wall such
that it is against the back refractory (see Figure 14.7).
Step 3.
Bend left and right refractory retainer tabs to keep side
pieces from tipping (see Figure 14.8).
REFRACTORY
REFRACTORY
RETAINER TAB
RETAINER TAB
Step 4.
Install logs according to the install manual.
CAUTION
Refractory is fragile! Carefully remove the refractory from the
packaging.
Step 1.
Remove the logs from the
fi
replace. Place the back wall
refractory centered against the back of the
fi
replace on
top of the grate tabs. While steadying the back piece
with one hand, place the left refractory against the
fi
re-
box left wall such that it is against the back refractory
(see Figure 14.6).
EMBER MATERIAL
Figure 14.5 Placement of Embers (SL-550TRS-E and SL-750TRS-E only)
NOTICE:
If vent run includes a PVI-SLP, ember material
should be placed along the back of the rear ports for lighting
purposes.