Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11
34
WHT
WHT
BLK
BLK
GRN wire
inside box
Copper
ground attached
to GRN screw with
GRN wire
14/2WG
Cover Plate
outside firebox
Romex
Connector
F. Junction Box Installation
If the box is being wired from the
OUTSIDE
of the appli-
ance:
• Remove the cover plate located on the outer shell - right
side. See Figure 10.6.
• Install the supplied Romex™ connector in the cover plate.
• Feed the necessary length of wire through the connector.
• Make all necessary wire connections and reattach the
cover plate to the outer shell.
If the box is being wired from the
INSIDE
of the appliance:
• Remove the screw attaching the junction box/receptacle
to the outer shell, rotate the junction box inward to
disengage it from the outer shell. See Figure 10.6.
• Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
• Feed the necessary length of wire through the connector.
• Make all necessary wire connections to the junction box/
receptacle and reassemble the junction box/receptacle
to the outer shell.
Figure 10.6 Junction Box Detail
Note:
Do NOT wire
110VAC to wall switch.
Figure 10.5.
BATTERY
OPERATION
SWITCH
“BATTERY ON”
POSITION
POSITION
CONTROL
BOX