Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13
20
D. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances to combustibles as specified. Framing or finishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Figure 5.3 Clearances To Combustible/Non-Combustible
Mantels Or Other Combustibles/Non-Combust-
ibles Above Appliance.
Mantels (Combustible/Non-Combustible)
Figure 5.4 Non-Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
UNLIMITED
TOP VIEW
18 cm
8 cm
MINIMUM
36 cm
MIN.
30 cm
MAX.
1,3 cm
Thick Wall
Sheathing
MEASUREMENT
FROM TOP OF
FIREPLACE
OPENING
Note:
For non-combustible fireplace finish material (marble,
stone, etc) specifications refer to Section 13.C.
Mantel Leg (Combustible/Non-Combustible)
8,90 cm
2,5 cm
AIR SPACE
NON-COMBUSTIBLE
BOARD SHIPPED
WITH APPLIANCE
2,5 cm
Figure 5.6 Non-Combustible Zone
Note:
AIR SPACE denoted in Figure 5.6 is defined by the
nailing tabs and metal standoffs.
Note:
Factory installed non-combustible board may only
be replaced with HHT product code
SUPERM-60
material
and must be fully replaced in its entirety.
Figure 5.5 Front Side Finishing Detail
2,5 cm
FRAMING
1,2 cm FACTORY-SUPPLIED
NON-COMBUSTIBLE BOARD
NAILING TAB