Figure 10.17 Venting through the wall
K. Install Horizontal Termination Cap
WARNING! Risk of Fire!
The telescoping flue section
of the termination cap MUST be used when connecting
vent.
• 3,8 cm minimum overlap of flue telescoping section
is required.
Failure to maintain overlap may cause overheating and
fire.
• Vent termination must not be recessed in the wall. Siding
may be brought to the edge of the cap base.
• Flash and seal as appropriate for siding material at
outside edges of cap.
• When installing a horizontal termination cap, follow the
cap location guidelines as prescribed by current local or
national codes and refer to Section 6 of this manual.
CAUTION! Risk of Burns!
Local codes may require in-
stallation of a cap shield to prevent anything or anyone
from touching the hot cap.
Note:
When using termination caps with factory-supplied heat
shield attached, no additional wall shield firestop is required on
the exterior side of a combustible wall.
INTERIOR
HEAT SHIELD OR
EXTENDED
HEAT SHIELD
WALL SHIELD
FIRESTOP
HEAT SHIELD
3,8 CM MIN.
OVERLAP
SHEATHING
SLIP SECTION
CAN BE EXTENDED
INNER VENT
OUTER VENT
EXTERIOR