24
Step 7. Finishing
Do not install a combustible mantel or other combustible
projection above the top of the unit unless it is a minimum
of 45 inches above the top. (See Figure 25)
WARNING: WHEN FINISHING THE FIREPLACE,
NEVER OBSTRUCT OR MODIFY THE AIR IN-
LET/OUTLET GRILLES IN ANY MANNER.
DO NOT
put any finishing material on the Vent Cap.
!
Figure 25. Combustible above Appliance
Figure 24. Fan Wiring Diagram
FAN
TEMPERATURE
SENSOR SWITCH
SPEED CONTROL
(RHEOSTAT)
JUNCTION BOX
NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105 C RATED WIRE.
O
JUNCTION BOX
VARIABLE SPEED CONTROL
TEMPERATURE
SENSOR SWITCH
WHT
GRN
BLK
BLK
110-120 VAC
BLOWER
BLOWER RECEPTACLE
BLK
BLK
BLK
BLK
WHT
GROUND
WHT
BLK
BLK
BLK
COMBUSTIBLE
PROJECTION
45” MIN.
UNIT TOP