background image

08/04

4004-001 Rev C

5

PATIO CAMPFIRE INSTALLATION INSTRUCTIONS

1. Burner Assembly

a.

All Models

1)

Remove the burner assembly and check for
damage. Do not use damaged components.

2)

Position the burner assembly in the desired
location.

This location must be adjacent to the gas supply
line.

You must have easy access to the gas valve control
knob after it is installed and connected the gas
supply because the ON/OFF gas valve is used to
turn the burner on and off.

b.

Natural Gas Models

1)

Connect the ON/OFF gas valve of the appliance to
the incoming gas supply line. See Figure 1. Make
certain all gas connections are tight.

2)

Turn the ON/OFF valve at the appliance slowly to
the “ON” position. All connections must be tightened
and checked for leaks with a commercially
available, non-corrosive leak check solution. Be
sure to rinse off the solution when done leak testing.

c.

LP Gas Models

1)

Make sure the tank valve is turned completely off
(clockwise).

2)

Ensure the tank valve has the proper external mating
threads (tank valve marked “USE WITH TYPE 1”).

3)

Inspect the hose shipped with the appliance for
any damage. Do not use if there is evidence of
damage.

4)

Connect the end of the hose onto the ON/OFF gas
valve of the appliance. Make sure it is secured tightly.

5)

Connect the regulator assembly to the tank valve.
Hand tighten only (clockwise). Do not use a wrench
to tighten! Use of a wrench may damage the quick
closing nut and result in a hazardous condition.
See Figure 2.

6)

Position the hose out of pathways where people
might trip over it or in areas where the hose might
be subject to accidental damage.

7)

Open the tank valve fully (counterclockwise). Turn
the ON/OFF valve slowly to the “ON” position.  All
connections must be tightened and checked for
leaks with a commercially available, non-corrosive
leak check solution. Be sure to rinse off the solution
when done leak testing.  If a leak is found, turn the
tank valve off and do not use the appliance until
repairs can be made.

Figure 1

Natural Gas Burner Assembly

Figure 2

Propane Burner Assembly

Summary of Contents for PATIO CAMPFIRE

Page 1: ...r s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier IMPORTANT Read al...

Page 2: ...nclosed area WARNING This log set must NOT be installed in an unvented appliance WARNING This appliance is not for use with solid fuel Rock Ring The following clearances to combustibles must be mainta...

Page 3: ...ng it into service It is recommended that cylinders that have not been used for extended periods of time also be purged before use Clothing or other flammable materials should not be placed on or near...

Page 4: ...CAMPFIRE INSTALLATION INSTRUCTIONS C COMPONENTS AND INSTALLATION The burner assembly and log assembly are packaged individually and shipped in one carton See illustrations below Burner Assemblies Log...

Page 5: ...d completely off clockwise 2 Ensure the tank valve has the proper external mating threads tank valve marked USE WITH TYPE 1 3 Inspect the hose shipped with the appliance for any damage Do not use if t...

Page 6: ...penings at floor level are in a side wall there must be a least two openings The bottom of the openings must be at floor level and the upper edge can t be more than 5 in 127 mm above the floor The ope...

Page 7: ...oken components b Position the log base over the burner making sure to align the dimple in the log base over the locating button on the burner top see burner assemblies page 4 c Position the logs by p...

Page 8: ...r s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to turn the gas control knob or valve Never use tools If the valve will not turn by hand don t try...

Page 9: ...likely to occur when using LP gas The soot should be cleaned off the surface of the logs periodically to prevent excessive buildup To clean the logs be sure the fire is out the gas supply is turned o...

Page 10: ...10 4004 001 Rev C 08 04 PATIO CAMPFIRE INSTALLATION INSTRUCTIONS G REPLACEMENT PARTS Log Assembly Log 1 Log 2 Log 3 Log 4 Log Base...

Page 11: ...2 Burner Assembly 35323 1 Y 3 Burner Weldment 35324 1 N 3 Burner Neck Gasket 17196 1 N 4 SMS 8x1 2 S Grip BO 12460 2 Y 5 Burner Neck Assembly 34465 1 Y Natural Gas Flex Tube Assembly 35326 1 Y LP Gas...

Page 12: ...d before Hearth Home Technologies has been afforded a reasonable opportunity to inspect the Product This warranty is limited to the replacement or repair of defective components or workmanship and Hea...

Reviews: