08/04
4004-001 Rev C
9
PATIO CAMPFIRE INSTALLATION INSTRUCTIONS
E. MAINTENANCE INSTRUCTIONS
1.
The appliance should be inspected before initial use and
inspected and cleaned at least annually by a qualified field
service person.
2.
Tampering with this appliance is
DANGEROUS
and voids all
warranties. Any component that is found to be faulty must be
replaced with an approved component.
3.
To obtain proper operation, it is imperative that the burner
flame characteristics are steady, not lifting or floating. Check
the burner flame patterns with Figure 5.
4.
Periodically remove the logs and examine the burner. If dirty,
clean with a soft brush. Also examine the area around the
burner air shutter. Any dirt or lint in this area should be
removed. This will ensure long life and trouble free operation.
When the appliance is put back in service, check the burner
flame patterns with Figure 5. Reinstall the logs as shown in
the log placement instructions.
5.
Periodically check the hose connecting the LP gas cylinder
to ensure it is not damaged in any way.
Figure 5 - Flame Patterns
Note:
Carbon (soot) may build up on the surfaces of the
logs with heavy use. This is more likely to occur when using
LP gas. The soot should be cleaned off the surface of the
logs periodically to prevent excessive buildup.
To clean the logs, be sure the fire is out, the gas supply is
turned off and the logs are cool to the touch. The soot can
then be brushed off with a dry bristle brush or cloth. Take
care while cleaning the logs as they can become damaged
if mishandled. Care should be taken to dispose of the soot
and cleaning materials properly. Keep away from clothing
and outdoor furniture.
F. HIGH ELEVATION INSTALLATION
For U.S. installation, this appliance is tested and approved for elevations from 0-2000 ft. When installing this appliance at an elevation
above 2000 ft, National Fuel Gas Codes require a decrease of the input rating by changing the existing burner orifice to a smaller size.
Input should be reduced 4% for each 1000 ft above sea level. Check with the local gas utility for proper orifice size identification.
For Canada, this appliance is certified for elevations from 0-4500 ft. When installing this appliance at an elevation between 0-4500 ft
in Canada, the input rating does not need to be reduced. When installing this appliance at an elevation above 4500 ft in Canada,
check with local authorities.
ORIFICE SIZES
Fuel
Orifice #
Orifice Size
Maximum Output
Propane Gas
#44
.086
60,000 BTUs/hr
Natural Gas
#27
.144
75,000 BTUs/hr