background image

08/04

4004-001 Rev C

3

PATIO CAMPFIRE INSTALLATION INSTRUCTIONS

B. SAFETY INFORMATION

The Patio Campfire has been tested in accordance with 

IAS US

requirements for Outdoor Gas Fireplaces, Draft 4-96

 and 

ANSI

Z21.58-1995/CGA 1.6-M96

 for Canada and has been listed by

Underwriters Laboratory (UL) for installation and operation as
described in these installation and operating instructions.

The installation must conform with local codes or, in the absence
of local codes, with the 

National Fuel Gas Code ANSI Z223.1 or

CAN/CGA-B149.1, National Gas Installation Code

 or 

CAN/CGA-

B149.2, Propane Installation Code

.

IMPORTANT:

 Installation of natural gas should be done by a

qualified installer, service agency or gas supplier.

The appliance and its manual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing
of the system at test pressures in excess of 1/2 psig (3.5kPa).

This appliance must be isolated from the gas supply piping
system by closing its manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal
to or less than 1/2 psig (3.5kPa).

Children and adults should be alerted to the hazards of high

surface temperatures and should stay away to avoid burns
or clothing ignition.

Young children should be carefully supervised when they

are in the area of the appliance.

Never leave the appliance unattended during operation.

Note: 

All new LP cylinders (and in many cases used cylinders)

may contain water, air or other contaminants. It is essential
that these substances be released before filling the cylinder
and placing into service. Water vapor present in the gas vapor
may cause the regulator to “freeze up” and cause an
interruption to the gas flow. This interruption will cause the
appliance to shut down. To prevent this from occurring, it is
essential that a qualified individual always purge a new tank
thoroughly before placing it into service. It is recommended
that cylinders that have not been used for extended periods of
time also be purged before use.

Clothing or other flammable materials should not be placed

on or near the appliance.

Any guard or other protective device removed for servicing

the appliance must be replaced prior to operating the
appliance.

Installation and repair should be done by a qualified service

person. The appliance should be inspected before use and
at least annually by a qualified service person. More frequent
cleaning may be required as necessary. It is imperative that
the control compartment, burners and circulating air
passageways of the appliance be kept clean.

Inspect the fuel supply connection (including the hose for

LP models) before each use of the appliance.

If it is evident there is excessive abrasion or wear, or the

hose is cut, it must be replaced prior to the appliance being
put into operation.

The pressure regulator and hose assembly supplied with

LP models must be used. Replacement pressure regulators
and hose assemblies must be those specified in this
manual

The LP gas supply cylinder used with LP models must be

constructed and marked in accordance with the
specifications for LP gas cylinders of the U.S. Department of
Transportation (DOT).

Cylinders must be stored outdoors in a well ventilated area

out of the reach of children. Disconnected cylinders must
have threaded valve plugs tightly installed and must not be
stored in a building, garage or any other enclosed area.

Storage of this appliance indoors is permissible only if it

has been disconnected from its fuel supply (natural gas line
or LP gas cylinder).

The LP gas cylinder supply system must be arranged for

vapor withdrawal.

The LP gas cylinder used must include a collar to protect the

cylinder valve.

When an LP model is not in use, the LP gas must be turned

off at the supply cylinder.

Note: 

Do not use this appliance if any part has been under

water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control
system and any gas control which has been under water.

Summary of Contents for PATIO CAMPFIRE

Page 1: ...r s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier IMPORTANT Read al...

Page 2: ...nclosed area WARNING This log set must NOT be installed in an unvented appliance WARNING This appliance is not for use with solid fuel Rock Ring The following clearances to combustibles must be mainta...

Page 3: ...ng it into service It is recommended that cylinders that have not been used for extended periods of time also be purged before use Clothing or other flammable materials should not be placed on or near...

Page 4: ...CAMPFIRE INSTALLATION INSTRUCTIONS C COMPONENTS AND INSTALLATION The burner assembly and log assembly are packaged individually and shipped in one carton See illustrations below Burner Assemblies Log...

Page 5: ...d completely off clockwise 2 Ensure the tank valve has the proper external mating threads tank valve marked USE WITH TYPE 1 3 Inspect the hose shipped with the appliance for any damage Do not use if t...

Page 6: ...penings at floor level are in a side wall there must be a least two openings The bottom of the openings must be at floor level and the upper edge can t be more than 5 in 127 mm above the floor The ope...

Page 7: ...oken components b Position the log base over the burner making sure to align the dimple in the log base over the locating button on the burner top see burner assemblies page 4 c Position the logs by p...

Page 8: ...r s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to turn the gas control knob or valve Never use tools If the valve will not turn by hand don t try...

Page 9: ...likely to occur when using LP gas The soot should be cleaned off the surface of the logs periodically to prevent excessive buildup To clean the logs be sure the fire is out the gas supply is turned o...

Page 10: ...10 4004 001 Rev C 08 04 PATIO CAMPFIRE INSTALLATION INSTRUCTIONS G REPLACEMENT PARTS Log Assembly Log 1 Log 2 Log 3 Log 4 Log Base...

Page 11: ...2 Burner Assembly 35323 1 Y 3 Burner Weldment 35324 1 N 3 Burner Neck Gasket 17196 1 N 4 SMS 8x1 2 S Grip BO 12460 2 Y 5 Burner Neck Assembly 34465 1 Y Natural Gas Flex Tube Assembly 35326 1 Y LP Gas...

Page 12: ...d before Hearth Home Technologies has been afforded a reasonable opportunity to inspect the Product This warranty is limited to the replacement or repair of defective components or workmanship and Hea...

Reviews: