NOTE: There are two T-POD versions depending on your pump voltage - 110volt and 

220 volt. MAKE SURE YOU HAVE THE RIGHT VOLTAGE T-POD FOR YOUR PUMP.

Using software and hardware ALREADY BUILT INTO your DIGITAL D or DX series 

HEAT SIPHON’s PLAYER CONTROL BOARD, your T-POD Accessory Kit minimizes 
your pump operating cost by providing a one-event-per-day pump timer with off cycle heat-

ing (PumpJump™) to maintain your pool at temperature 24 hours/day -  7 days/week.

T-POD is designed to let you control your pool or spa pump’s daily start-up and run times in 6 minute in-

crements from OFF to 24 hrs ON. You set the “On In” - “X.X HRS” and the “For” X.X” hours using the Player 
“UP” and “DOWN” Keys on your Heat Siphon. (X.X represents the hour numbers you set such as 10.2 or 4.5 
etc.) 

In addition, the T-POD enables the “PumpJump™” feature built into your Heat Siphon Player Control to 

ensure that your pool temperature will be maintained even when you scheduled your pump to be off. It does 
this by turning your pool pump on every 30 minutes and briefly running it long enough to clear the plumbing 
lines and check the temperature. If the water is still warm, the pump is shut off.  If the pool water is  more than 
1.5° F below set-point, the pool pump will continue to run and your Heat Siphon will turn on and run until the 

pool reaches temperature. Then both Heat Siphon and pump will shut off. To enable PumpJump™ just PRESS 
BOTH KEYS once and the blue LED will light indicating it is in PumpJump™. Repeat keypress to disable it.

Installing your T-POD Timer kit is EASY however we recommend that you contract a licensed Electrician 

for the electric power wiring. Here are the five basic steps:

Mount your T-POD on a wall next to your pool pump power wires and within 8-10 
feet of  Heat Siphon Player Control so the supplied cable will reach it.

Cut into the pool pump power supply wiring and connect your T-POD between the 
breaker and your pump. Your T-POD has 4 screw-down terminals and two 1/2” con-

duit nipples to make wiring easy.

Run the attached 24 volt control wire to Your Heat Siphon and screw down the pre-
stripped leads into the POD terminals on your Player Board.

Install your Easy-Clock plug-in board into the D-sub connector on the back of your 
Heat Siphon’s Player Board.

Program your Pump on time and run time using your Player Up and Down keys.

POOL

MAIN 

POWER 

BREAKER

BOX

24 VOLT

220 volt

POOL PUMP

Installing Your T-POD Timer Kit

Hard-wired Pump Timer/ PumpJump™ on Your D/DX Series Digital HEAT SIPHON®

Summary of Contents for T-POD

Page 1: ...s shut off If the pool water is more than 1 5 F below set point the pool pump will continue to run and your Heat Siphon will turn on and run until the pool reaches temperature Then both Heat Siphon and pump will shut off To enable PumpJump just PRESS BOTH KEYS once and the blue LED will light indicating it is in PumpJump Repeat keypress to disable it Installing your T POD Timer kit is EASY however...

Page 2: ...ecommended that a Licensed Electrician perform all Power Wiring 1TURN OFF ALL POWER to your Pool Pump circuit breaker and prepare the wir ing to be cut and spliced or run new wire from your pump breaker disconnect switch to the T POD and from the T POD to the pump as shown 2Connect the two wires from the breaker to the two screw down terminals ON THE RIGHT SIDE of the T POD marked FROM POWER LINE ...

Page 3: ...nel will be prevented from getting into the Player pocket 5Loosen the set screw on the two POD terminals on the Player board Insert the red and white wires into the POD terminals and screw down the set screws Pull on the wires to make sure they are securely fastened to the Player board 6Leave the door open to per form the next steps PART D Installing the Easy Clock Board Tools Required Small Flat ...

Page 4: ... Heat Siphon is on tPod run For 12 5H pump will run for 12 5 hours On In 12 0 minus turned on 12 hours ago Troubleshooting You don t see tPod on the LED display after pressing either the UP or DOWN key Make sure the Easy Clock Card is firmly seated in the connector Reboot the software by 1 pressing both keys then while flashing then 2 pressing either key until OFF is displayed and stops flashing t...