CONTROL OVERVIEW
PART 9: CONTROL OVERVIEW
(CONTINUED)
CLOCK DATE
08/28/2009 Fr 10:01A
D. PROGRAMMING THE SYSTEM SETTING
Note: Programming of the control is not possible when the unit is firing. Make sure any input such
as the thermostat is turned off, so the boiler will remain idle to allow programming.
To access The
System Setting Program
the user will need to press the
ENTER
Key for 4 seconds until
the display shows the following:
ENTER MENU CODE
000
Using the arrow keys on the display, log in your
System Menu Access Code “925”.
To confirm code,
press the
ENTER KEY
to access System Setting Program Navigation menu.
ENTER MENU CODE
925
E. SYSTEM SETTING PROGRAM NAVIGATION
Once the
System Menu Access Code
is confirmed, the user can now start to set the System
Parameters Menu. Use the arrows keys on the display to navigate through the different program set-
tings. To change a setting, press the
ENTER KEY
to change an appliance setting. System settings can
be
increased
by pressing the
UP ARROW
and
decreased
by pressing the
DOWN ARROW
on the dis-
play. Listed below are the System Settings that can be programmed into the control.
Function 1
Factory Program Mode
MODE
1
PHOENIX
This screen indicates that the control is configured correctly. Do not change this screen
Function 2
Max Tank Temp
MAX TANK TEMP
2
180 °F
Description: Sets the overall all tank temperature maximum limit. Factory Default of 180 °F (Range
95 °F to 185 °F)
Function 3
DHW Offset Temp
OFSET
3
0 °F
Description: Not Used.