7
Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. W • 8/14
B. Tempered Glass Speci
fi
cations
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous loca-
tions such as bathtub enclosures as de
fi
ned by the Con-
sumer Product Safety Commission (CPSC). The tempered
glass has been tested and certi
fi
ed to the requirements
of
ANSI Z97.1
and
CPSC 16 CFR 1202
(Safety Glazing
Certi
fi
cation Council
SGCC# 1595
and
1597
. Architectur-
al Testing, Inc. Reports
02-31919.01
and
02-31917.01
).
This statement is in compliance with
CPSC 16 CFR Sec-
tion 1201.5
“Certi
fi
cation and labeling requirements”
which refers to
15
U.S. Code
(USC) 2063
stating “…Such
certi
fi
cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
C. BTU Speci
fi
cations
MODELS:
6000C-IPI, 8000C-IPI
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Direct Vent Heater
STANDARD:
ANSI Z21.88b-2008 • CSA 2.33a-2008
This product is listed to ANSI standards for “Vented Gas
Fireplace Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.
A. Appliance Certi
fi
cation
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
D. High Altitude Installations
NOTICE:
If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
• In CANADA: Reduce input rate 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
Check with your local gas utility to determine proper
ori
fi
ce size.
NOTICE:
This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
1
1
Listing and Code Approvals
Models
(U.S. or Canada)
Maximum
Input
BTU/h
Minimum
Input
BTU/h
Ori
fi
ce
Size
(DMS)
6000C-IPI (NG)
US
(0-2000 FT)
30,000
16,000
37
CANADA
(2000-4500 FT)
27,000
14,400
38
6000C-IPILP
US
(0-2000 FT)
29,000
17,000
52
CANADA
(2000-4500 FT)
26,100
15,300
53
8000C-IPI (NG)
US
(0-2000 FT)
35,000
19,000
33
CANADA
(2000-4500 FT)
31,500
17,100
34
8000C-IPILP
US
(0-2000 FT)
34,000
17,000
50
CANADA
(2000-4500 FT)
30,600
15,300
51