27
Self-Contained Spot Merchandiser
rrd
Outputs restart after doA alarm
(n; Y) n = outputs not affected by the doA alarm; Y = outputs
restart with the doA alarm
HES
Delta temperature during an Energy Saving cycle
(-30.0 to 30.0°C; -54 to 54°F) Sets the increasing value of the
setpoint [SET+HES] during the Energy Saving cycle.
OTHER
Adr
Serial address
(1 to 247) Identifies the instrument address when connected
to a MODBUS compatible monitoring system.
PbC
Type of probe
(ntC, CtC) It allows to set the kind of probe used by the instru-
ment: ntC = NTC-EU probe, CtC = NTC-US probe. Set this
PbC parameter to CtC to support standard CPC temp sensors
- factory default.
onF
ON/OFF key enabling
(nU; oFF; ES) nU = disabled; oFF = enabled; ES = not set it
dP1
Thermostat probe display
dP2
Evaporator probe display
dP3
Third probe display (optional)
dP4
Fourth probe display
rSE
Real setpoint
Shows the setpoint used during the energy saving cycle or
during the continuous cycle.
rEL
Software release for internal use
Ptb
Parameter table code
Read only
Appendix C: Factory Settings
Label
Name
Range
Value
Level
Setting
SEt
Setpoint
LS to US
-5.0
---
-20
rtc*
Real time clock menu
-
-
Pr1
-
Hy
Differential
1 to 255°F
2.0
Pr1
5
LS
Minimum setpoint
-58°F to SEt
-50
Pr2
-58
US
Maximum setpoint
SEt to 230°F
110
Pr2
230
ot
Thermostat probe calibration
-120 to 120°F
0.0
Pr1
0.0
P2P
Evaporator probe presence
n = not present; Y = present
Y
Pr1
Y
oE
Evaporator probe calibration
-120 to 120°F
0.0
Pr2
0.0
P3P
Third probe presence
n = not present; Y = present
n
Pr2
n
o3
Third probe calibration
-120 to 120°F
0
Pr2
0
P4P
Fourth probe presence
n = not present; Y = present
n
Pr2
n
o4
Fourth probe calibration
-120 to 120°F
0
Pr2
0
ods
Outputs delay at start up
0 to 255 min
0
Pr2
0
AC
Anti-short cycle delay
0 to 50 min
1
Pr1
0
rtr
P1-P2 percentage for regulation
0 to 100 (100=P1, 0=P2)
100
Pr2
100
CCt
Continuous cycle duration
0.0 to 24.0 hr
0.0
Pr2
0.0
CCS
Setpoint for continuous cycle
-67 to 302°F
-5
Pr2
-20
Con
Compressor ON time with faulty
probe
0 to 255 min
15
Pr2
0
CoF
Compressor OFF time with faulty
probe
0 to 255 min
30
Pr2
0
CF
Temperature measurement unit
°C to °F
°C
Pr2
°F
rES
Resolution
in = integer; dE = decimal point
dE
Pr1
in