Installation Instructions
Your new Aquarius
DI Water Heating System has been pre-wired and tested prior to
shipment. After proper installation, the unit will supply your heated de-ionized water
needs for years to come.
1. Verify that the minimum operating requirements are available. (See the
Facility Diagram and the Electrical Schematic drawings in
SECTION II
for
more information.)
2. Install the unit in its permanent location. Please ensure that the
recommended space requirements required for servicing of the system has
been met, as detailed in the Aquarius Space Requirement drawings. Please
provide adequate space to allow the door to open fully or open to 90
o
.
3. The unit must be secured using the included plinth base mounting brackets
to be compliant with SEMI S2-0715. It must be secured to the floor to
minimize possible tip over during a seismic event. See the figure below for
more information regarding unit attachment.
4. Connect the incoming and outgoing water lines. Use only the connection
types provided with the unit. (Refer to the drawing section of this manual to
for system connections.)