11
598-1373-01
SPECIFICATIONS
This product is to be installed indoors only.
Electrical Input
........................................................................................................................
120V, 60 Hz.
Fluorescent Load ..............................................................................................
Up to 400 Watts Maximum
Motor Load
...........................................................................................................
Up to 1/8 HP Maximum
Incandescent ...................................................................................
Up to 500 Watts Maximum at 120VAC
On-Time
...................................................................................
Selectable, approximately 5 to 30 minutes
Photocell Sensor
....................................................................
From full daylight to less than 1 FC (10 lux)
Coverage ........................................
up to 15 ft. (4.6 m) at 150°, up to 30 ft. (9.1 m) in front of the sensor
SyMPTOM
POSSIBLE CAUSE
SOLUTION
Light does not stay
on in AUTO mode.
1. Motion has stopped in the room.
2. TIME control is set for too short a
delay.
1. Continue movement.
2. Set switch TIME control to longer
time period.
Light turns on in
daylight in the AUTO
mode.
LIGHT control not set properly.
Turn the LIGHT control counter-
clockwise (see
Light Sensitivity Level
,
page 8).