3
598-1321-01
Bottom of Sensor
ON-TIME
10
TEST
TEST AND ADJUSTMENT
NOTE: Sensor has a 1
1
/
2
minute warm up period
before it will detect motion. When first turned
on, wait 1
1
/
2
minutes.
❒
Turn on the circuit breaker and light switch.
❒
Set the ON-TIME control to the TEST position.
Motion
Motion
The detector is most sensitive to motion across its field
of view.
Maximum Range
Maximum
Coverage Angle
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where
pets or traffic may trigger the control.
•
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
50 ft.
(15.2 m)
8 ft.
(2.4 m)
180°
Least Sensitive
Most Sensitive
Sensor
❒
Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒
Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cover-
age area.
Keep the sensor at
least 1" (2.5 cm) away from
the lamps.
❒
Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒
Set the ON-TIME control to 10
minutes.
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 50 ft. (15.2 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . Up to 180°
Electrical Load . . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
maximum each lamp holder.]
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 10 minutes
Range . . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features
in products previously sold.
Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage