background image

2

598-1324-01

❒ 

Drill out the holes if needed 
to mount the backplate to the 
junction box.

INSTALLATION

For easy installation, select an existing light with a wall 
switch for replacement.
For best performance, locate the fixture about 8 ft. (2.4 m) 
above the ground.
CAUTION: The sensor must be mounted below the 
lamp housing for wall installations.

  Remove the existing light fixture.

  Strip about 5/8" insulation from the existing junction 

box wiring.

  Route  the  light  control’s  wires  through  the  large 

hole in the gasket.

  Twist the junction box wires and fixture wires together 

as shown. Secure with wire connectors.

  Align the light control cover plate and cover plate 

gasket and the junction box. Insert and tighten the 
mounting screws.

  If not installed on a weatherproof box or if an adaptor 

plate is used, 

caulk the wall plate and mounting 

surface with silicone weather sealant.

M

ount

 

the

 L

ight

 C

ontroL

Cover Plate 

Gasket

The  halogen  light  must  be 
mounted horizontally (+/- 4°).

 

RIGHT 

WRONG

B

uLB

 i

nstaLLation

 

and

 r

eLaMping

  When relamping, 

turn power off and let the fixture 

cool.

  Remove the screw that holds the glass cover shut. 

Remove the old bulb by pushing the bulb towards 
the right until the left side of the bulb is clear of the 
left socket.

CAUTION to avoid fire or burn hazards:

•  Allow  fixture  to  cool  before  touching. The  bulb 

and fixture operate at high temperatures.

•  Keep fixture at least 2" (5 cm) from combustible 

materials. Do not aim at objects closer than 3 feet 
(1 m).

•  Re-lamp with type T 150W (or less) halogen 120 

VAC lamp only.

For under eave installation, the sensor head must 
be rotated
 as shown in the next two steps for proper 
operation and to avoid the risk of electrical shock.

Black to Black

White to White

 

Rotate  the  sensor  head  to-
wards the clamp screw joint.

 

Then  rotate  the  sensor 
head  counterclockwise 
180° so the controls face 
down.

Controls

Junction box ground wire to 
green ground wire on fixture.

W

ire

 

the

 L

ight

 C

ontroL

If  the  sensor  pops  out  of  the  ball  joint,  loosen  the 
clamp screw and push the sensor back into the ball 
joint. Tighten the clamp screw when done.

Clamp Screw

Controls

  To insert the new bulb, push the bulb into the right 

socket  so  the  bulb  fits  completely  into  the  left 
socket.

  Check that the bulb is seated properly.

❒ 

Close the glass cover. Replace screw.

 WARNING: Turn power off at the fuse or circuit 

breaker.

Summary of Contents for BL-5511

Page 1: ... intended for use with the enclosed gasket and with a junction box marked for use in wet locations The backplate has knockouts so the sensor can be mounted on most junction boxes In some applications a universal adaptor plate may be needed Adaptors are available at Home Centers and Electrical Supply Stores If you get confused while switching modes turn the power off for one minute then back on Aft...

Page 2: ...screw that holds the glass cover shut Remove the old bulb by pushing the bulb towards the right until the left side of the bulb is clear of the left socket CAUTION to avoid fire or burn hazards Allow fixture to cool before touching The bulb and fixture operate at high temperatures Keep fixture at least 2 5 cm from combustible materials Do not aim at objects closer than 3 feet 1 m Re lamp with type...

Page 3: ...emperature rapidly such as heating vents and air conditioners These heat sources could cause false triggering Areas where pets or traffic may trigger the control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point other lights at the sensor 50 ft 15 2 m The control is most sensitive to motion across it Least Sensitive Most Sensitive Motion Sensor Motio...

Page 4: ...ed Repair service adjustment and calibration due to misuse abuse or negligence light bulbs batteries and other expendable items are not covered by this warranty Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety This warranty does not include reimbursement for incon venience installation setup time loss of use unauthorized serv...

Page 5: ...odalidades del interruptor Apague el interruptor por un segundo y préndalo de nuevo Mueva el interruptor de tiempo ON TIME a 10 minutos El modo manual funciona sólo por la noche porque la luz del día pone al detector en modo AUTOMATICO Apague el interruptor por un segundo y vuélvalo a prender El modo manual funciona sólo cuando el interruptor de tiempo ON TIME está en la posición de 10 minutos PRU...

Page 6: ...de empalmes con losalambresdelcontroldeluz Unalosyasegúrelos con un conector de alambre Instalación y Cambio De Bombilla Elcabledeconexiónatierradelacajadeem palmes al tornillo verde de conexión a tierra del aparato o al cable verde si lo tiene Instale El Control De Luz Alinee la placa cubertora del control de luz y el empaque de la placa cubertora y los agujeros de la caja de empalmes Asegúrelos ...

Page 7: ...tor en su posición ajustando el tornillo de la grampa No apriete de masiado el tornillo Fije el control de DURA CIÓN ON TIME a 10 minutos Angulo Máximo de Cobertura Alcance Máximo Lo menos sensible Lo más sensible Detector Movimiento El detector es más sensible al movimiento lateral Movimiento NOTA El detector tiene un período de cerca de 1 1 2 minutos de calentamiento antes de detectar movimiento...

Page 8: ...egido sin cargo para Ud No cubierto Servicio de reparación ajuste y calibración debido al mal uso abuso o negligencia bombillas baterías u otras partes fungibles no están cubiertas por esta garantía Los Servicios no autorizados o modificaciones del producto o de cualquier componente que se provee invalidarán esta garantía en su totalidad Esta garantía no incluye reembolso por inconveniencia instal...

Page 9: ...jour remet le capteur en mode AUTO Mettre l interrupteur hors circuit pendant une seconde plus en circuit pour alterner entre les modes AUTO et MANUEL Le mode manuel ne fonctionne que lorsque l interrupteur ON TIME est aux positions 10 PRIORITÉ MANUELLE AUTO TEST Luminairehalogènecom pact de 150W à détecteur de mouvement Le luminaire de sécurité au quartz à détecteur de mou vement déclenche un écl...

Page 10: ...t dans la douille gauche S assurer que l ampoule est bien insérée et appuyée Replacer le couvercle de verre Aligner la plaque de garde de la commande d éclairage la garniture de la plaque de garde et la boîte de jonction Insérer et serrer les vis de montage Si le luminaire n est pas monté sur une boîte de jonction étanche aux intempéries ou si une plaque d adaptationestutilisée calfeutrerlaplaquem...

Page 11: ...cher le dispositif d arrêt Ne pas pointer d autres appareils d éclairage vers le détecteur 15 2 m 2 4 m REMARQUE Le capteur doit se réchauffer 1 1 2 minute avantdepouvoirdétecterlemouvement Lorsque l appareil est mis en circuit ou changé de mode attendre 1 1 2 minute Bas du détecteur ESSAIS ET RÉGLAGES Mettre en circuit le disjoncteur et l interrupteur d éclairage Portée maximale Angle de couvertu...

Page 12: ...e main d oeuvre sera corrigée gratuitement Exclusions de la garantie Réparations réglage et calibrage dus à une mauvaise utilisation un mauvais traitement ou à la négligence Les ampoules les piles et des autres articles non durables ne sont pas couverts par cette garantie Le service non autorisé ou la modification du produitoud unoul autredesescomposantsfournisinvalideratotalementlaprésentegaranti...