background image

4

598-1324-01

SYMPTOM
Light  will  not 
come on.

Light comes on 
in daylight.

Light comes on 
for no apparent 
reason.

POSSIBLE CAUSE
1.  The halogen lamp is positioned too 

close to the light control’s sensor or 
pointed at nearby objects that cause 
heat to trigger the sensor 

(Reposition 

the  lamp  away  from  the  sensor  or 
nearby objects)

.

2.  Light control’s sensor is pointed toward 

a heat source like an air vent, dryer 
vent, or brightly-painted heat-reflective 
surface 

(Reposition sensor)

.

3.  On-time set too high 

(Reduce Time 

setting)

.

1.  Heat or light from the halogen lamp 

may  be  turning  the  light  control  on 
and  off 

(Reposition  the  lamp  away 

from the sensor)

.

2.  Heat  being  reflected  from  other 

objects  may  be  affecting  the  light 
control 

(Re-aim sensor)

.

3.  Light  control  is  in  the  TEST  mode 

and warming up 

(Flashing is normal 

under these conditions)

.

SYMPTOM
Light stays on 
continuously.

Light  flashes 
on and off.

POSSIBLE CAUSE
1.  Light switch is turned off.
2.  Halogen  lamp  is  loose  or  burned 

out.

3.  Fuse  is  blown  or  circuit  breaker  is 

turned off.

4.  Daylight turn-off is in effect 

(Recheck 

after dark)

.

5.  Incorrect circuit wiring, if this is a new 

installation.

6.  Not  aimed  correctly 

(Re-aim  the 

sensor to cover desired area)

.

1.  Light  control  may  be  installed  in  a 

relatively dark location.

2.  Light control is in TEST 

(Select 1, 5 

or 10 minutes for AUTO time)

.

1.  Light control’s sensor may be detect-

ing small animals, swaying trees, or 
automobile traffic 

(Re-aim sensor)

.

2.  Sensitivity is set too high 

(Reduce 

sensitivity)

.

TROUBLESHOOTING GUIDE

TWO YEAR LIMITED WARRANTY

This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state 
to state or province to province.
For a period of two years from the date of purchase, any malfunction caused by factory defective parts or workmanship 
will be corrected at no charge to you.
Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, 
and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of 
any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for incon-
venience, installation, setup time, loss of use, unauthorized service, or return shipping charges.
This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components 
that a customer uses in conjunction with our products.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY 
WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR 
ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, 
OR CONSEQUENTIAL DAMAGES.
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO 
LIABILITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL 
DAMAGES,  INCLUDING  BUT  NOT  LIMITED TO  ANY  LOSS  OF  BUSINESS  OR  PROFITS,  WHETHER  OR  NOT 
FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential dam-
ages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for 
all warranty requests.

TECHNICAL SERvICE

Please call 1-800-858-8501 (English speaking only) for assistance before returning 

product to store.

If you experience a problem, follow this guide. You may also want to visit our Web site at: 

www.hzsupport.com. 

If the problem persists, call* for assistance at 

1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST 

(M-F). You may also write* to:
HeathCo LLC, P.O. Box 90004, Bowling Green, KY 42102-9004
ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of Pur-
chase, and Place of Purchase.

No Service Parts Available for this Product

Summary of Contents for BL-5511

Page 1: ... intended for use with the enclosed gasket and with a junction box marked for use in wet locations The backplate has knockouts so the sensor can be mounted on most junction boxes In some applications a universal adaptor plate may be needed Adaptors are available at Home Centers and Electrical Supply Stores If you get confused while switching modes turn the power off for one minute then back on Aft...

Page 2: ...screw that holds the glass cover shut Remove the old bulb by pushing the bulb towards the right until the left side of the bulb is clear of the left socket CAUTION to avoid fire or burn hazards Allow fixture to cool before touching The bulb and fixture operate at high temperatures Keep fixture at least 2 5 cm from combustible materials Do not aim at objects closer than 3 feet 1 m Re lamp with type...

Page 3: ...emperature rapidly such as heating vents and air conditioners These heat sources could cause false triggering Areas where pets or traffic may trigger the control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point other lights at the sensor 50 ft 15 2 m The control is most sensitive to motion across it Least Sensitive Most Sensitive Motion Sensor Motio...

Page 4: ...ed Repair service adjustment and calibration due to misuse abuse or negligence light bulbs batteries and other expendable items are not covered by this warranty Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety This warranty does not include reimbursement for incon venience installation setup time loss of use unauthorized serv...

Page 5: ...odalidades del interruptor Apague el interruptor por un segundo y préndalo de nuevo Mueva el interruptor de tiempo ON TIME a 10 minutos El modo manual funciona sólo por la noche porque la luz del día pone al detector en modo AUTOMATICO Apague el interruptor por un segundo y vuélvalo a prender El modo manual funciona sólo cuando el interruptor de tiempo ON TIME está en la posición de 10 minutos PRU...

Page 6: ...de empalmes con losalambresdelcontroldeluz Unalosyasegúrelos con un conector de alambre Instalación y Cambio De Bombilla Elcabledeconexiónatierradelacajadeem palmes al tornillo verde de conexión a tierra del aparato o al cable verde si lo tiene Instale El Control De Luz Alinee la placa cubertora del control de luz y el empaque de la placa cubertora y los agujeros de la caja de empalmes Asegúrelos ...

Page 7: ...tor en su posición ajustando el tornillo de la grampa No apriete de masiado el tornillo Fije el control de DURA CIÓN ON TIME a 10 minutos Angulo Máximo de Cobertura Alcance Máximo Lo menos sensible Lo más sensible Detector Movimiento El detector es más sensible al movimiento lateral Movimiento NOTA El detector tiene un período de cerca de 1 1 2 minutos de calentamiento antes de detectar movimiento...

Page 8: ...egido sin cargo para Ud No cubierto Servicio de reparación ajuste y calibración debido al mal uso abuso o negligencia bombillas baterías u otras partes fungibles no están cubiertas por esta garantía Los Servicios no autorizados o modificaciones del producto o de cualquier componente que se provee invalidarán esta garantía en su totalidad Esta garantía no incluye reembolso por inconveniencia instal...

Page 9: ...jour remet le capteur en mode AUTO Mettre l interrupteur hors circuit pendant une seconde plus en circuit pour alterner entre les modes AUTO et MANUEL Le mode manuel ne fonctionne que lorsque l interrupteur ON TIME est aux positions 10 PRIORITÉ MANUELLE AUTO TEST Luminairehalogènecom pact de 150W à détecteur de mouvement Le luminaire de sécurité au quartz à détecteur de mou vement déclenche un écl...

Page 10: ...t dans la douille gauche S assurer que l ampoule est bien insérée et appuyée Replacer le couvercle de verre Aligner la plaque de garde de la commande d éclairage la garniture de la plaque de garde et la boîte de jonction Insérer et serrer les vis de montage Si le luminaire n est pas monté sur une boîte de jonction étanche aux intempéries ou si une plaque d adaptationestutilisée calfeutrerlaplaquem...

Page 11: ...cher le dispositif d arrêt Ne pas pointer d autres appareils d éclairage vers le détecteur 15 2 m 2 4 m REMARQUE Le capteur doit se réchauffer 1 1 2 minute avantdepouvoirdétecterlemouvement Lorsque l appareil est mis en circuit ou changé de mode attendre 1 1 2 minute Bas du détecteur ESSAIS ET RÉGLAGES Mettre en circuit le disjoncteur et l interrupteur d éclairage Portée maximale Angle de couvertu...

Page 12: ...e main d oeuvre sera corrigée gratuitement Exclusions de la garantie Réparations réglage et calibrage dus à une mauvaise utilisation un mauvais traitement ou à la négligence Les ampoules les piles et des autres articles non durables ne sont pas couverts par cette garantie Le service non autorisé ou la modification du produitoud unoul autredesescomposantsfournisinvalideratotalementlaprésentegaranti...

Reviews: